MayPole MP7423 Скачать руководство пользователя страница 2

 

GENERAL INFORMATION 

1. 

Retain these instructions for future use. 

2. 

Store this product in a dry place to avoid moisture damage. 

3. 

There are no user-serviceable parts in this product. Opening the case is dangerous and should therefore 
only be carried out by qualified persons. Resultant damage to the product will result in the loss of your 
guarantee. 

4. 

Do not use this product if it is damaged in any way. 

5. 

Only use this product for the purposes described in this instruction booklet. Failure to do so will result in 
the loss of your warranty. The manufacturer will not accept liability for damage to the charger, persons or 
property resulting from incorrect usage. 

 

SAFETY

 

The use of safety goggles and gloves when working with lead acid batteries is strongly advised. Avoid contact 
with the electrolyte as this is acidic and is likely to cause burns to the skin or clothes. If this occurs you should 
rinse the affected area with plenty of water immediately.  In the event of burns to the skin, medical advice 
should be sought if the symptoms persist.  

 
DISPOSAL

 

In the event that this product must be disposed of, an authorised place for the recycling of electrical and 
electronic  appliances  must  be  sought.    Contact  your  local  authority  for  information  concerning  local 
Household Recycling Centres with applicable facilities. 

This product must not be disposed of with general domestic waste.

 

 
RECOMMENDED USES 

This product is suitable for charging 6V and 12V lead acid, sealed lead-acid, maintenance-free and AGM 
batteries  of capacities 1.2Ah to 120Ah (Ampere hours).   Check  with  your device manufacturer if you are 
unsure about the suitability of this charger for use with your device.  
 

BATTERY CHARGING INSTRUCTIONS 

Please  read  your  vehicle  manufacturer’s  instructions  for  further  information  and  advice  regarding  the 
disconnection of the battery for charging purposes. 
 

IMPORTANT:

  This model  will  only  recover  12V  batteries  with  a minimum residual  voltage  of  7.5V,  or  6V 

batteries  with  a  minimum  residual  voltage  of  4V.  If  the  residual  voltage  is  lower  than  above  figures,  the 
charger will not operate. 

NOTE :

 This charger operates automatically and will change operating status without 

warning. 
 
Maintain as much distance as is practical between the battery and charger. Monitor the temperature of the 
battery during charging. If the temperature of the battery exceeds 40

0

C cease charging until the battery has 

cooled to a safe temperature. Failure to do so may result in the battery exploding.  
 
Batteries  store  large  amounts  of  energy. Avoid  short  circuits  which  could  result  in  a  dangerous  electrical 
discharge that could result in personal injury and / or damage to equipment and property.  The charger will 
automatically detect the voltage (6V or 12V) and diagnose the condition of your battery, the first stage of the 
5 Step charging cycle (as listed in part 4). 
 

1. 

PREPARATION  OF  THE  BATTERY 

In the case of lead-acid batteries, firstly remove the caps from each cell and check the level of liquid.  If it is 
below the recommended level, top up with ionized or distilled water. 

UNDER NO CIRCUMSTANCES SHOULD TAP WATER BE USED 