23
IMPORTANT!
NEVER SET THE "ELEVATOR" SWITCH TO "0"
OTHERWISE THE SWIVEL DRIVE MAY BE DAMAGED.
d) Mixing and moistening
If your machine is fitted with a moistener, you are able to
moisten the finished soil after it has been mixed.
To do this, take the mixer into operation in the normal way and
let it mix the contents. Set the "Discharging" switch to "0" to
prevent the MAYER SOIL MIXER from discharging its contents
after the first mixing cycle.
Start another mixing cycle and open the ball cock on the
moistener.
You can regulate the amount of water using the straight-way
valve.
Close the ball cock again after the mixing cycle with moistening
has finished. Leave the setting on the straight-way valve
unchanged in order to have the same level of moisture in the
next batch.
We recommend you mix the moistened soil again before
discharging it.
To discharge the soil, turn the "Discharging" switch to "Time".
The soil hopper is now discharged under the control of the
automatic timer.
e) Mixing and automatic moistening
It is possible to fit the MAYER soil mixer with an automatic
moistening system as a special option.
With the automatic moistening system, the soil is moistened
when the mixing cycle starts and watering stops when the
mixing cycle does.
The "Discharging" switch should be set to "0" for this.
Now close the straight-way valve and mix the moistened
material again. Set the "Discharging" switch to "Time" in order
to discharge the hopper.