Maxxair SKYMAXX LX 97000 Скачать руководство пользователя страница 6

FOR INSTALLATION OF SKYMAXX LX PLUS 
ROOFLIGHT 

WARNING!

 

TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE 
THE FOLLOWING:

 

Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction. 

CAUTION!

 

Disconnect main vehicle power before 

connecting 12 volt DC power to the 

SKYMAXX 

ROOFLIGHT

STEP 10 

Insert the 12 volt DC power supply wires into the large 
diameter hole in the interior flange, allowing 4 to 6 inches of 
wire to hang out. Note: Red wire from the wall control and black 
wire from the negative terminal. 

STEP 11 

Insert the ceiling flange into the opening, lining up the flanges.  

STEP 12 

Referring to the screw lengths in the table of STEP 5, use the 
proper length screws depending on your roof thickness to 
secure the ceiling flange to the rooftop flange, taking care not 
to overtighten the screws to avoid cracking or deforming the 
ceiling flange and rooftop flange. 

STEP 13 

Optional: Install the screws to secure the ceiling flange to the 
caravan ceiling. If the ceiling flange does not lay flat to the 
ceiling, you may want to install screws to prevent gapping. 

STEP 14 

Using the supplied wire nuts, connect the 12 volt DC power 
supply wires to the LED light wires. Red wire from the wall 
control to the red wire (pos) on the LED lights, and the black 
wire from the negative terminal. 

STEP 15 

To assemble the Interior Shroud to the Ceiling Flange, line up 
the flanges with the channels on the Ceiling Flange. Make sure 
the power wires slide to the inside of the interior assembly and 
do not become pinched or entangled. Secure in place by 
pressing firmly on the Interior Shroud. This ensures that the 
clips on the Interior Shroud will engage the channels on the 
ceiling flange to lock it in place 

This completes the installation of the MAXXAIR SKYMAXX  Plus ROOFLIGHT. 

 

 

Содержание SKYMAXX LX 97000

Страница 1: ...to 60 mm maximum The LED lighted Rooflight requires a minimum 12 Volt DC 2 amp service Confirm that the circuit you intend to use will accommodate the additional load Circuit must be fused and use appropriate gauge stranded wire for electrical connections NOTE Wall Control for LED lights must be provided by installer NOTE THE ROOFLIGHT MUST BE CLOSED PRIOR TO TRANSPORTING OR MOVING THE CARAVAN WAR...

Страница 2: ...This page intentionally left blank ...

Страница 3: ...materials containing solvents such as or similar to Xylene Toluene Methyl Ethyl Ketone MEK Acetate or Acetone as they can damage the flange Also Polysulfide Thiokol type sealants must be avoided If in doubt please contact the manufacturer of your caravan for further information STEP 3 Insert the SKYMAXX ROOFLIGHT into the roof opening with the hinged section facing the front of the vehicle with th...

Страница 4: ...table of STEP 6 use the proper length screws depending on your roof thickness to secure the ceiling flange to the rooftop flange taking care not to overtighten the screws to avoid cracking or deforming the ceiling flange and rooftop flange STEP 8 Optional Install the screws to secure the ceiling flange to the caravan ceiling If the ceiling flange does not lay flat to the ceiling you may want to in...

Страница 5: ... amount of screen versus shade can be adjusted to your preference To close the SKYMAXX ROOFLIGHT move the handle from the slot and pull the handle toward the open side of the Rooflight Push the handle above the button which will lock the Rooflight lid closed NOTE THE ROOFLIGHT MUST BE CLOSED PRIOR TO TRANSPORTING OR MOVING THE CARAVAN USER SERVICING INSTRUCTIONS Cleaning of your MAXXAIR SKYMAXX RO...

Страница 6: ...ceiling flange to the rooftop flange taking care not to overtighten the screws to avoid cracking or deforming the ceiling flange and rooftop flange STEP 13 Optional Install the screws to secure the ceiling flange to the caravan ceiling If the ceiling flange does not lay flat to the ceiling you may want to install screws to prevent gapping STEP 14 Using the supplied wire nuts connect the 12 volt DC...

Страница 7: ...CING INSTRUCTIONS Cleaning of your MAXXAIR SKYMAXX ROOFLIGHT may be achieved with mild soap and water only DO NOT USE ABRASIVE CLOTH ON ROOFLIGHT COVER It is advisable when the Rooflight is open to keep the screen and or shade covering the Rooflight opening Should you have questions please contact AIRXCEL MAXXAIR Customer Service at 316 832 4357 or rvpsupport airxcel com SKYMAXX 2 YEAR LIMITED WAR...

Страница 8: ...For additional product information please visit www AIRXCEL com AIRXCEL INC RV Products Division MAXXAIR 3050 N St Francis St Wichita KS 67219 316 832 3400 PLACE CONSUMER LABEL HERE ...

Отзывы: