INSTALLATION INSTRUCTIONS
STEP 1
SKYMAXX Model
Roof Opening
00-97000, 00-97100
00-97010, 00-97110
27.56 in. x 19.70
(700 mm x 500 mm)
Refer to the above table for
roof size opening. If you are
replacing another type already installed, remove the old
existing roof vent. Remove all old roof sealant for a minimum of
2 inches (5 cm) entirely around the roof opening.
STEP 2
Prior to installing the
SKYMAXX
ROOFLIGHT over the roof
opening, apply
a continuous strip of a flexible non-hardening
sealing compound (e.g. SikaLastomer-710) to the underside of
the flange in the grooved space.
CAUTION!
When installing your MAXXAIR ROOFLIGHT,
only use a caulking/sealant compatible with the flange (plastic
product) and the roof surface. DO NOT use materials
containing solvents such as or similar to Xylene, Toluene,
Methyl Ethyl Ketone (MEK), Acetate or Acetone as they can
damage the flange. Also, Polysulfide (Thiokol) type sealants
must be avoided.
If in doubt, please contact the manufacturer of your caravan
for further information.
STEP 3
Insert the
SKYMAXX
ROOFLIGHT into the roof opening with
the hinged section facing the front of the vehicle with the ceiling
flange centered in the opening. Press down on the flange to
compress the sealant to seal to the roof.
STEP 4
After the
SKYMAXX
ROOFLIGHT has been installed, remove
the excess caulk that may have squeezed out. Using a sealer
such as Dicor self-leveling lap sealant or similar caulking, apply
a bead (approximately 0.25 in./5 mm dia.) along the outside
edge of the flange all the way around the rooflight.
THIS COMPLETES THE ROOF TOP PORTION OF THE INSTALLATION
Skip to page 6 for interior installation of SKYMAXX LX Plus
Содержание SKYMAXX LX 97000