          If there  is data in the memory,  the latest  recorded  set of
          measurement  which  are the Systolic  rate, Diastolic  rate,
          heart  pulse,  will the memory  will automatically  the 

memory  will automatically1  minute.  (60 sec.)

(2) Press  RECALL  button  to read the next line of stored  data.

The data called  up on the display  is numbered  accordingly.
After  reading  the recalled  data as rotatory  48-set of the
stored  data,  press  RECALL  to switch  to normal  time.

(3) To discontinue  in the midst  of reading  of the data,  press

START/STOP  button  to power  off.

c. Erasing  data:

(1). Take  out the batteries  and then refill  2 pcs batteries  again.
(2). To discontinue  if the data is erased.   Press  RECALL  button,

no data should  show  up on the screen.

D.  To  change  batteries

:

When  "      " show  up on the display,  the battery  is weak.
Change  the batteries  or it will not be possible  to take blood
pressure  measurement. 
All batteries  used must  be the same  type.  Do not mix alkaline,
standard  (carbon- zinc)  or rechargeable  (cadmium)  batteries.
Do not mix old and new batteries.

10.  MAINTENANCE:

• 

Use a piece  of cloth  with water  or mild cleansing  agent  to clean  the

       case and then use a piece  of dry cloth  to wipe  it dry.

• 

Do not use gas or any strong  cleansers  in cleaning.

• 

When  the unit is not to be used for a long time,  remove  the batteries.

   (Leaking  of battery  liquid  can cause  trouble)

11.  SAFE- KEEPING:

• 

Always  keep  the unit in the carrying  case after its use.

• 

Do not put the item directly  under  the sunlight,  in high

     temperature,  or humid  and dusty  places.

• 

Do not store  in extremely  low (less  than - 20 C) or high

     (more  than 60 C) temperature.

12.  TO  PREVENT  MALFUNCTION:

• 

Do not in any way twist  the wrist  cuff

• 

Do not start the air pressure  when  the wrist  cuff is not wrapped

       around  the wrist.

• 

Do not attempt  to disassemble  or change  any parts  of the

    monitor  including  wrist  cuff.

• 

Do not drop the product  or put it through  strong  impact.

13.  WARNING:

• 

The device  measures  the blood  pressure  of adult  only.

• 

The device  is not supposed  to be used if your wrist  has any

       wound  or injury.

• 

In the event  of the cuff pumping  up and not stopping,  please 

       open  the cuff at once.

14.  SPECIFICATIONS:

Model  No.
Method  of Measurement
Range  of Measurement

Accuracy  Calibration
Fuzzy  Pressure

: HL-168B,  HL-168C
: Oscillometric
: Pressure  0~300mmHg,  pulse
40~200  beats/minute
: Pressure  +/-3mmHg,  Pulse  +/-5%
: Automatic  Re-inflation  pump  system
: Automatic  inflation  (Air Pump)
: Automatic  air release  control  valve
: Automatic  exhaust  valve
: Liquid  Crystal  Digital  Display
: 48-set
: L70 x W72  x H29mm
: Approx.  130g  including  batteries
: Wrist  circumference  approx.
135~195mm
: +10  to +40 , 30~85%  RH
: -20  to +50 , 10-95%RH
: 2x 'AAA'  (3.0V)  Alkaline  battery
: Approx.  250 times  measurement
: Carrying  case,  instruction  manual,
2 pcs "AAA"  battery