background image

4

 

Ventamatic, Ltd.

 | P.O. Box 728, Mineral Wells, TX  76068 ▪ Phone: (800) 433-1626 ▪  www.MYMAXXAIR.com

 

 

Step 2: Cut the Shutter Opening

 

Cut through ceiling along lines using a 
circular saw. Measure depth of drywall 
and adjust the saw so you only cut the 
drywall and avoid the joists. 

 

Carefully remove the drywall from the 
opening

*Note*   Make sure the exposed joist is 
centered if doing the joist-in installation. 

 

Step 3: Cut the Ceiling Joist 

(For Joist-Out Installation Only)

 

 

 

Stabilize the joists using 2 X 6 lumber to 
bridge the joist about six inches away from 
either side of the opening.

 

Attach stabilizers to the joists with #12D nails 
or 2 1/2” deck screws. 

 

Mark two lines on the joists to be cut about      
1 1/2” away from either side of the opening. 

 

Cut along the lines using a saber saw. Make 
sure cuts are perpendicular and accurate.

 

 

Step 4: Frame the Shutter Opening 

 

Use lumber of the 

same dimensions as your ceiling joists 

and fasten them to the edges of the frame 

opening using #12D nails. 

 

Fasten the sheetrock to the new frame using 1 1/2” ring shank drywall nails. 

 

Seal any gaps between headers and joists with caulk or foam insulation. 

_

*

Note*   Remove the two bridges from the previous step if doing a joist-out installation.

______________ 

 

 

                          

 

Joist-In Installation 

Joist-Out Installation 

Содержание CX242DDWT

Страница 1: ...ng into wall or ceiling do not damage electrical wiring and other hidden utilities d WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE...

Страница 2: ...ft and 8 10 sq ft of Net Free Exhaust Area 30 in Fans Requires attic space of at least 1800 sq ft and 10 12 sq ft of Net Free Exhaust Area 36 in Fans Requires attic space of at least 3000 sq ft and 14...

Страница 3: ...st in or joist out option below Remove all insulation above the installation site Joist In Installation Align shutter vein with ceiling joist in the center of the shutter opening Draw a line on the ce...

Страница 4: ...s away from either side of the opening Attach stabilizers to the joists with 12D nails or 2 1 2 deck screws Mark two lines on the joists to be cut about 1 1 2 away from either side of the opening Cut...

Страница 5: ...n the frame and facing Ensure that there is still a minimum of 36 clearance between the fan blades and attic roof Step 6 Prepare and Install Fan Assembly Belt Drive Models Remove hardware and remount...

Страница 6: ...the outer edges of the shutter frame Install the shutter using the white headed wood screws provided with your fan Caulk the seams for an airtight seal Step 8 Wiring Instructions Note All wiring suppl...

Страница 7: ...to overheat Insufficient intake or exhaust Net Free Air Open more doors and windows or increase the amount of ventilation in the attic Check the bearing assembly for resistance on belt driven models...

Страница 8: ...ed for the repair or replacement and return to you of any part or component not covered by this warranty including parts or components damaged by you The company reserves the right to demand and recei...

Отзывы: