AT INTERFACE DESCRIPTION
5 – 3
TIMING PARAMETERS
MODE 0
MODE 1
MODE 2
MODE 3
MODE 4
t0
Cycle Time (min)
600 ns
383 ns
240 ns
180 ns
120 ns
t1
Address valid to DIOR-/DIOW- setup (min)
70 ns
50 ns
30 ns
30 ns
25 ns
t2
DIOR-/DIOW- 16-bit (min)
165 ns
125 ns
100 ns
80 ns
70 ns
t2i
DIOR-/DIOW- recovery time (min)
70 ns
25 ns
t3
DIOW- data setup (min)
60 ns
45 ns
30 ns
30 ns
20 ns
t4
DIOW- data hold (min)
30 ns
20 ns
15 ns
10 ns
10 ns
t5
DIOR- data setup (min)
50 ns
35 ns
20 ns
20 ns
20 ns
t6
DIOW- data hold (min)
5 ns
5 ns
5 ns
5 ns
5 ns
t6Z
DIOR- data tristate (max)
30 ns
30 ns
30 ns
30 ns
30 ns
t9
DIOR-/DIOW- to address valid hold (min)
20 ns
15 ns
10 ns
10 ns
10 ns
tRd
Read Data Valid to IORDY active (min)
0
0
0
0
0
tA
IORDY Setup Time
35 ns
35 ns
35 ns
35 ns
35 ns
tB
IORDY Pulse Width (max)
1250 ns
1250 ns
1250 ns
1250 ns
1250 ns
PIO Timing
Figure 5 - 2
PIO Data Transfer To/From Device