UP/DOWN A, B, C 

Output 

mode 

setting

K-1               

  

P

Q

A

UP/DOWN A, B, C 

Output 

mode 

setting

K-2               

D

L

H

  ★ 

Total and Preset Counter Operation

  ★ 

Batch Counter Operation

6、

Sequence Charts

Output mode A: signal ON delay 1

Output mode A-1: signal ON delay 2

Output mode A-2: Power ON delay 1

Output mode A-3: Power ON delay 2

Output mode b: Repeat cycle 1

Output mode b-1: Repeat cycle 2

Output mode d: Signal OFF delay

Output mode E: Interval

Output mode F: Cumulative

Z mode : ON/OFF –duty adjustable flicker

  ★ 

Timer Operation

Output Mode toff: flicker OFF start 

Output Mode ton: flicker ON start

  ★ 

Twin Timer Operation

  ★ 

2-Stage Timer Operation 

A Mode: Signal ON delay

F-1 Mode: Cumulative

  ★ 

Counter Input Modes and Present Value

UP / DOWN A 

command input mode

UP / DOWN B 

individual input mode

UP / DOWN C

quadrature input mode

                 UP (increment) Mode    

                 CP1: count input

                 CP2: prohibit(gate)input

                 UP (increment) Mode

                 CP1: prohibit(gate)input

                 CP2: count input

             DOWN(decrement) mode

             CP1: count input

             CP2: prohibit(gate)input

                 DOWN(decrement) mode

                 CP1: prohibit(gate)input

                 CP2: count input

  ★ 

Counter Output Mode Setting

Operation for 1-stage models is the same as that for OUT2.

When using a 2-stage model as a 1-stage counter, or dual counter, total and preset counter, OUT1 and 

OUT2 turn ON and OFF.

UP

DOWN

UP/DOWN A, B, C 

Output 

mode 

setting

N

  

F

C

R

  ★ 

Dual Counter Operation

Dual Count Calculating Mode = ADD

Dual count value = CP1 PV + CP2 PV

Dual Count Calculating Mode = SUB

Dual count value = CP1 PV -CP2 PV

  ★ 

Tachometer Output Mode Settings

Measurement value

(Lower-limit)

OUT1 set value

(upper-limit)

OUT1 set value

OUT 1

OUT 2

ON condition for OUT1: measurement value≤OUT1 set value

ON condition for OUT2: measurement value≥OUT2 set value

OUT2 set value

Measurement value

OUT1 set value

Condition
OUT1 ON

OUT2 ON

OUT1 set value≤OUT2 set value
OUT set value≤Measurement value≤

OUT2 set value

Measurement value<OUT1 set value

Measurement value >OUT2 set value

Measurement value <OUT2 set value

Measurement value >OUT1 set value

OUT1 set value >OUT2 set value

OUT2 set value≤Measurement value≤

OUT1 set value

OUT 1

OUT 2

(Upper-limit)

OUT2 set value

Measurement value

(Lower-limit)

OUT1 set value

OUT 1 

OUT 2 

(Upper-limit)

OUT2 set value

Measurement value

(Lower-limit)

OUT1 set value

OUT 1

OUT 2

ON condition for OUT1: measurement value≥OUT1 set value

ON condition for OUT2: measurement value≥OUT2 set value

ON condition for OUT1: Measurement value≤OUT1 set value

ON condition for OUT2: Measurement value≤OUT2 set value

7、

Input Connections

TC-Pro482 Timer/Counter/Tachometer operation manual

8、

Dimensions and Panel Cutouts

Note: M3 terminal screw (effective length: 8mm) 

No-voltage 

Inputs 

(NPN Input)

External voltage 

External voltage 

Gate CP1

Signal CP2

Reset 1
Reset 2

Open Collector 

(connection to NPN open collector output 

sensor)

External voltage

External voltage

Gate CP1

Signal CP2

Reset 2
Reset 1

Voltage Inputs 

(connection to a voltage output sensor)

Gate CP1

Signal CP2

Reset 2
Reset 1

Contact Input

External voltage

External voltage

Internal circuit

Gate CP1

Signal CP2

Reset 2
Reset 1

Two-wire Sensor

Voltage Inputs (PNP Input)

External voltage

External voltage

Gate CP1

Signal CP2

Reset 2
Reset 1

No-contact Input 

(NPN Transistor) 

(Connection to NPN open 

collector output sensor)

External voltage

External voltage

Gate CP1

Signal CP2

Reset 2
Reset 1

No-contact Input

(PNP Transistor) 

(connection to a voltage 

output sensor) 

Gate CP1

Signal CP2

Reset 2
Reset 1

Contact Input

Parameter name Parameter

Setting range (use   key to select)

Default value

Tachometer 

output mode

hilo/area/hihi/lolo

hilo

Counting speed

30Hz/10KHz

30Hz

Decimal point 

position

----/---.-/--.--/-.---

----

Prescale value

000.001~999.999

001.000

Average 

processing

off/2/4/8

off

Auto-zero time

00.01~99.99

99.99

Startup time

00.01~99.99

00.00

NPN/PNP

Input time

NPN/PNP

NPN

Key protect level

kp-1/kp-2/kp-3/kp-4/kp-5

kp-1

60.25

110.5

98

12.5
7.25

53

48

55.5

65 mm 以上

20 mm 以上

45 mm 

65 mm 以上

45 mm 

45 mm 

+ 0.6

- 0

+ 0.6

- 0

+ 0.6

- 0