UP
DOWN
UP/DOWN A, B, C
Output
mode
setting
K-1
P
Q
A
UP/DOWN A, B, C
Output
mode
setting
K-2
D
L
H
★
Total and Preset Counter Operation
★
Batch Counter Operation
6、
Sequence Charts
Output mode A: signal ON delay 1
Output mode A-1: signal ON delay 2
Output mode A-2: Power ON delay 1
Output mode A-3: Power ON delay 2
Output mode b: Repeat cycle 1
Output mode b-1: Repeat cycle 2
Output mode d: Signal OFF delay
Output mode E: Interval
Output mode F: Cumulative
Z mode : ON/OFF –duty adjustable flicker
★
Timer Operation
Output Mode toff: flicker OFF start
Output Mode ton: flicker ON start
★
Twin Timer Operation
★
2-Stage Timer Operation
A Mode: Signal ON delay
F-1 Mode: Cumulative
★
Counter Input Modes and Present Value
UP / DOWN A
command input mode
UP / DOWN B
individual input mode
UP / DOWN C
quadrature input mode
UP (increment) Mode
CP1: count input
CP2: prohibit(gate)input
UP (increment) Mode
CP1: prohibit(gate)input
CP2: count input
DOWN(decrement) mode
CP1: count input
CP2: prohibit(gate)input
DOWN(decrement) mode
CP1: prohibit(gate)input
CP2: count input
★
Counter Output Mode Setting
Operation for 1-stage models is the same as that for OUT2.
When using a 2-stage model as a 1-stage counter, or dual counter, total and preset counter, OUT1 and
OUT2 turn ON and OFF.
UP
DOWN
UP/DOWN A, B, C
Output
mode
setting
N
F
C
R
★
Dual Counter Operation
Dual Count Calculating Mode = ADD
Dual count value = CP1 PV + CP2 PV
Dual Count Calculating Mode = SUB
Dual count value = CP1 PV -CP2 PV
★
Tachometer Output Mode Settings
Measurement value
(Lower-limit)
OUT1 set value
(upper-limit)
OUT1 set value
OUT 1
OUT 2
ON condition for OUT1: measurement value≤OUT1 set value
ON condition for OUT2: measurement value≥OUT2 set value
OUT2 set value
Measurement value
OUT1 set value
Condition
OUT1 ON
OUT2 ON
OUT1 set value≤OUT2 set value
OUT set value≤Measurement value≤
OUT2 set value
Measurement value<OUT1 set value
Measurement value >OUT2 set value
Measurement value <OUT2 set value
Measurement value >OUT1 set value
OUT1 set value >OUT2 set value
OUT2 set value≤Measurement value≤
OUT1 set value
OUT 1
OUT 2
(Upper-limit)
OUT2 set value
Measurement value
(Lower-limit)
OUT1 set value
OUT 1
OUT 2
(Upper-limit)
OUT2 set value
Measurement value
(Lower-limit)
OUT1 set value
OUT 1
OUT 2
ON condition for OUT1: measurement value≥OUT1 set value
ON condition for OUT2: measurement value≥OUT2 set value
ON condition for OUT1: Measurement value≤OUT1 set value
ON condition for OUT2: Measurement value≤OUT2 set value
7、
Input Connections
TC-Pro482 Timer/Counter/Tachometer operation manual
8、
Dimensions and Panel Cutouts
Note: M3 terminal screw (effective length: 8mm)
No-voltage
Inputs
(NPN Input)
External voltage
External voltage
Gate CP1
Signal CP2
Reset 1
Reset 2
Open Collector
(connection to NPN open collector output
sensor)
External voltage
External voltage
Gate CP1
Signal CP2
Reset 2
Reset 1
Voltage Inputs
(connection to a voltage output sensor)
Gate CP1
Signal CP2
Reset 2
Reset 1
Contact Input
External voltage
External voltage
Internal circuit
Gate CP1
Signal CP2
Reset 2
Reset 1
Two-wire Sensor
Voltage Inputs (PNP Input)
External voltage
External voltage
Gate CP1
Signal CP2
Reset 2
Reset 1
No-contact Input
(NPN Transistor)
(Connection to NPN open
collector output sensor)
External voltage
External voltage
Gate CP1
Signal CP2
Reset 2
Reset 1
No-contact Input
(PNP Transistor)
(connection to a voltage
output sensor)
Gate CP1
Signal CP2
Reset 2
Reset 1
Contact Input
Parameter name Parameter
Setting range (use key to select)
Default value
Tachometer
output mode
hilo/area/hihi/lolo
hilo
Counting speed
30Hz/10KHz
30Hz
Decimal point
position
----/---.-/--.--/-.---
----
Prescale value
000.001~999.999
001.000
Average
processing
off/2/4/8
off
Auto-zero time
00.01~99.99
99.99
Startup time
00.01~99.99
00.00
NPN/PNP
Input time
NPN/PNP
NPN
Key protect level
kp-1/kp-2/kp-3/kp-4/kp-5
kp-1
60.25
110.5
98
12.5
7.25
53
48
55.5
65 mm 以上
20 mm 以上
45 mm
65 mm 以上
45 mm
45 mm
+ 0.6
- 0
+ 0.6
- 0
+ 0.6
- 0