Timer

TH5C

Operation Manual

1

Panel Function

Upper display (PV)

Displaying counting value or
parameter 

Below display (SV)

Displaying setting value or parameter 

Shift key

Moving digit or switching display 
( pushing it for 3  sec to enter set 
mode )

Decreasing key

Increasing key

Rst

Reset key

Use for resetting or entering SV

LED

Run

flickering when counting

Out

lighting when output “on”

K/P

lighting when key locked

Reset

lighting when reset operation

Start

lighting when starting

Gate

lighting when stopping

H

lighting when hour selected

M

lighting when minute selected

S

lighting when second selected

Run
Out
K / P

Rst

SET

Rst
Start
Gate

H
M
S

TH5C

2

Set Time Method

Setting time can be changed during counting or stop counting.

Pushing          1 sec for LED flickering then push          or 

to increase or decrease the set time.

Rst

Pushing          to move digit position, it is cycle .
It must push          key to enter the SV after setting.

3

Parameter Flow Chart & Function

Setting value can be changed during counting or stop counting

Pushing          key for 3 sec then use          &          key to select the mode.

Push 3 sec

Returning to initial 
display after 20 sec 
no operation.

Time ranges

Time range selection

9.999sec

9999min

99.99sec

999.9hr

999.9sec

9999hr

9999sec

99min59sec

999.9min

99hr59min

S

S

M
S

…….

H
M

Use                    setting time range.

Select time range

Up / Down counting

Output mode

Output time

Input time

Key lock mode

Output contactor

Return 1tE (time range)

Use                    setting up / down counting.

Up                Down

Use                    setting output mode.

Select  time operation
* Refer to output mode diagram. TH5C without A1, A2, A3, B1, B2, C, D, F 

A

A1

A2      A3      b       b1      b2      C       d        E       F

Use                    setting time range.

* Output mode C, D, E, F without this function

Hold        0.1S        0.5S        1S        5S        10S      15S        20S

Use                    setting time range.

* 1ms=1/1000sec     * TH5C-8 without this function

1ms         20ms

ALL        UNLOCK        RESET        ADJ        SET

Use                    setting lock mode.

* Push          +          for 3 sec to perform lock or release lock

Use                    setting the output contactor.

* TH5C-8S and TH5C-11S without this function

2C          1A1C

http://www.maxthermo.com

4

Timing Charts

Either one-shot output or sustained output can be selected

Timing starts when the start signal goes ON.
While the start signal is ON, the timer starts
when the power comes ON or when the
reset input goes OFF.
The control output is controlled using a 
sustained or one-shot time period.

Timing starts when the start signal goes ON.
and is reset when the start signal goes OFF
While the start signal is ON, the timer starts
when the power comes ON or when the
reset input goes OFF.
The control output is controlled using a
sustained or one-shot time period.

Mode A :
Signal ON Delay
(Timer resets when
power comes on)

Mode A1 :
Signal ON Delay2
(Timer resets when
power comes on or
when START signal 
goes off)