DIGITAL TIMER INSTRUCTIONS (T4, T7)

1. CONNECT BATTERY

Open lid and attach battery to the snap, and then
insert battery in the holder.

2. SETTING THE TIME

The blue buttons on the side adjust the
time up and down left of the colon.  To
program the digits right-of the colon, hold
down the green “stop/start” button while
adjusting the blue buttons.  Model T7 will
have buttons on the circuit board inside.

3. SELECTING PROGRAM

• Different modes are selected by removing the

jumpers from the pins. (jumpers are located inside the box)

• JUMPER “

A

”  on the pins selects minutes /seconds.  For minutes/hours, remove

jumper “

A

”.

• Other jumpers provide the logic according the this summary table.

 Some cycles intentionally do not allow cancellation.  If allowed, 

canceling a cycle is done by 

holding

 the green “stop/start” button for 

about 2 seconds.  Display will flash the last reading and buzzer 
sounds.

4. OTHER

• For battery powered units, the alarm volume will diminish when voltage is low.

START / STOP

UP

DOWN

MODE

JUMPER

DESCRIPTION

B

C

D

1

ON

ON

ON

MANUAL CYCLE STOP - CAN CANCEL

2

OFF

ON

ON

MANUAL CYCLE STOP - CAN NOT CANCEL

3

ON

OFF

ON

REPEATING 2-SECOND RELAY PULSES

4

OFF

OFF

ON

ALTERNATING RELAY CYCLE -ON, THEN OFF

5

ON

ON

OFF

AUTOMATIC CYCLE STOP - CAN CANCEL 

6

OFF

ON

OFF

AUTOMATIC CYCLE STOP - CAN NOT CANCEL.

7

ON

OFF

OFF

GUARD DUTY

8

OFF

OFF

OFF

CUSTOM

Sep 18, 2014