16
Troubleshooting
S
E
C
T
I
O
N
7
1. When I enter [0013] PC4164-433 options, the keypad gives me a
long beep.
You cannot enter ESNs unless the PC4164-433 wireless receiver is enrolled. See section
2 for instructions on enrolling the PC4164-433 module.
2. I have entered the ESN for the device but when I violate the device,
the zone does not show open on the keypad.
Check the following:
•
Check that you are looking at a keypad on the same partition as the device you are testing
•
Check that the ESN has been entered correctly
•
Check that the zone is assigned to one or more partitions
3. When I try a module placement test I get no result or “Bad” results.
Check the following (see sections 4.1 and 4.2 for more information on testing devices):
•
Verify that you are testing the correct zone
•
Verify that the correct ESN was entered when the device was enrolled
•
Verify that the device is in range of the PC4164-433 receiver. Try testing the device in
the same room as the receiver
•
Confirm that the PC4164-433 receiver is properly connected to the Combus (see
section 2 for PC4164-433 receiver setup and wiring instructions)
•
Check that you are testing the zone correctly (see sections 4.1 and 4.2 for testing
instructions)
•
Check that the batteries are working and installed correctly
•
Look for large metal objects that may be preventing the signal from reaching the
PC4164-433 receiver
The device must be located where consistent “Good”or “Fair” results are obtained. If
several devices show “Bad” results, or if panic pendants and wireless keys operate
inconsistently, move the receiver. See section 2.3 for tips on choosing a mounting location
for the PC4164-433 receiver.
4. The LED on the motion detector does not turn on when I walk in
front of the unit.
The LED is for walk test purposes only. See your WLS904(P)(L)-433
Instruction Sheet
for
walk test instructions.
5
S
E
C
T
I
O
N
2
Getting Started
Diagram 1
This section describes how to set up and enroll the PC4164-433 module.
2.1 Unpack the PC4164-433 Receiver
Check that the following parts are in your PC4164-433 package:
•
PC4164-433 PCB
•
PC4164-433 plastic cabinet
•
2 antennas
2.2 Install the Antennas
Attach both antennas to the terminals marked ANT1 and ANT2, (not GND1 and GND2).
Install the antennas ONLY as shown in the following diagrams:
DO NOT install the antennas this way:
2.3 Find a Mounting Location for the PC4164-433
NOTE:
Do not permanently mount the PC4164-433 now. Mount the PC4164-433 receiver after
you have done placement tests with all the wireless devices (see sections 4.1 and 4.2).
Find a place that is:
•
Dry
•
Central to the proposed placement of all wireless devices
•
As high as possible
•
Far from sources of interference, including: electrical noise such as computers,
televisions and electric motors in appliances and heating and air conditioning units;
large metal objects like heating ducts and plumbing which may shield the antenna.
Make sure that electrical wires will not run over the antenna(s) of the module when it is
mounted.
When mounting the PC4164-433 in a basement, place the module as high and as close to
the underside of the first floor as possible. The range of the module will be reduced if
the unit is mounted below ground level.
2.4 Connecting the PC4164-433
The PC4164-433 is connected to the control panel via
the Combus.
CAUTION: Remove all power from the panel while
connecting modules to the Combus.
Wire the PC4164-433 to the Combus of the PC4010/
PC4020/P-16128 according to diagram 1:
Combus to
PC4010/PC4020/P-16128
Main Control Panel
https://www.e-camere.ro/alarma-antiefractie/module/DSC/PC-4164/