20
Chapter 4 Specification
3-Water Cooling Condition
Dew Point
Environment
Temperature
Max Relative Humidity
10%
20%
30%
40%
50%
60%
70%
80%
90%
95%
10℃
-20
-11.9
-6.8 -3.0
0.6
2.6
4.8
7.6
8.4
9.2
15℃
-16.4
-7.9
-2.4
1.5
4.7
7.3
9.6
11.6
13.4
14.2
20℃
-12.5
-3.7
1.9
6.0
9.25
12.0
14.4
16.4
18.3
19.2
25℃
-8.7
0.5
6.2
10.5
13.8
16.7
19.1
21.3
23.2
24.1
30℃
-5.0
4.6
10.5
15.0
18.4
21.4
23.9
26.2
28.2
29.1
40℃
2.6
12.7
19.1
23.8
27.6
30.7
33.5
35.9
38.0
39.0
50℃
10.0
20.8
27.6
32.6
36.7
40.0
43.0
45.6
47.9
49.0
Operation Temperature Range
CAUTION :
◎ This chart can be consulted for the dew point (temperature at which
moisture will precipitate or condense out of ambient air) in different
working environment. If the temperature of the laser is lower than the
crossing temperature in the chart, there is risk of condensation within the
laser.
No. Characteristics
Min.
Typ.
Max.
Unit
1
Cooling Method
Water Cooling
2
Cooling Water Temperature
22
24
26
℃
3
Water Pressure
4
5
bar
4
3000W/4000W
Water Flow Rate
40
L/min
5
3000W Power Consumption of
Chiller
4
P
4000W Power Consumption of
Chiller
5
P