22
Chapter 4 Specification
2 -General Characteristic Parameters
No.
Characteristics
Test
conditions Min. Nom. Max. Unit
1
Operating Voltage
MFSC-1000X(G4.0)
200
220
240
VAC
Operating Voltage
MFSC-1500X(G4.0)
200
220
240
Operating Voltage
MFSC-1500X(G4.0) (optional)
360
380
440
2
Input Power
MFSC-1000X(G4.0)
100% Output
3.2
KW
Input Power
MFSC-1500X(G4.0)
100% Output
5.0
3
Operating Ambient
Temperature
10
40
℃
4
Operating Ambient
Relative Humidity
10
85
%
5 Cooling Method
Water-cooling
6 Storage Temperature
-10
60
℃
7 Dimensions
482.6*550*133 (W*D*H)
mm
8
Weight MFSC-1000X(G4.0)
32±2
kg
Weight MFSC-1500X(G4.0)
36±2
3-Water Cooling Condition
No.
Characteristics
Min.
Unit
1
Cooling Method
Water Cooling
2
Ambient Temperature
≥ 30
< 30
℃
Chiller Set Temperature
Summer 26 Winter 22
℃
3
Hydraulic pressure
≥ 3
bar
4
MFSC-1000X (G4.0) Water Flow Requirements
10
L/min
MFSC-1500X (G4.0) Water Flow Requirements
15
5
MFSC-1000X (G4.0) Chiller Rated Cooling
Capacity Requirements
2.5
kw
MFSC-1500X (G4.0) Chiller Rated Cooling
Capacity Requirements
3.5
kw
CAUTION :
◎
The Chiller needs to meet the requirements of the above table under the
conditions of a circulating temperature of 40 ° C and an outlet temperature of 26 ° C.
◎
The above recommended water pressure requires the pressure drop of the main
line Δp ≤ 0.5bar. If this value is exceeded, the main circuit water pressure should be
increased accordingly.