5. When the conversation has ended Press and hold the P-T-T of the microphone press and hold 

the # key for 1 or 2 seconds to end the call. Release the P-T-T when the call has ended.   

 
 

Clearing a Dialed Number   

When a number has been accidentally entered during auto dial a press and release of the CLR 
key will delete an individual number. A press and hold of the CLR key will clear the entire dialed 
number.  

To Store a Number in Memory   

1. Dial the desired number. Entered number will show in the radio display.   
2. Press and release the STR key.   
3. Press and release any number 0 – 9 to store the number, * and # cannot be used for storing a 

number. STORed will show in the radio display indicating the number has been stored in 

memory under that key.   

 

To Recall a Stored number from Memory   

1. Press and release the RCL key.   
2. Press and release the number key from which a number has been stored. 
3. Press SND to dial the recalled number.   

 

If a number has been accidentally recalled repeat steps 1. and 2. until the   
proper number has been recalled.   

Clearing a Stored Number   

1. Press and release the RCL key.   
2. Press and release the number key from which a number has been 

stored. The stored number will show in the radio display. 
 

3. Press and hold the CLR key to remove the stored number. A newnumber can now be entered 

and stored in that location. 

 
FCC Licensing   

The Federal Communications Commission requires the operator of this radio be properly 
licensed under the applicable Part and/or Parts of the FCC Rules and Regulations.   

Consult with your Maxon Dealer, or contact the nearest FCC field office for information about 
obtaining a license.   

Service  

Содержание SM5402

Страница 1: ...SM5402 Operating Instructions...

Страница 2: ...and 800 MHz frequencies personal two way communication devices including the popular FRS Family Radio Service and GMRS radios and a variety of wireless communication products two way voice messaging h...

Страница 3: ...authorized by the manufacturer for use with this radio ALWAYS use Maxon authorized accessories Use of unauthorized accessories can cause the FCC RF exposure compliance requirements to be exceeded DO n...

Страница 4: ...UTION DO not operate the radio near electrical blasting caps or in an explosive atmosphere CAUTION DO not operate the transmitter of any radio unless all RF connectors are secure and any open connecto...

Страница 5: ...ions SM5402 Features z Conventional radio operation z 9 character display with icons z Wideband frequency separation z Programmable output power z Programmable 12 5 25 kHz channel spacing z Multiple f...

Страница 6: ...W nominal 10 Modulation Type F3E Audio Power 6W Internal 16W speaker Intermediate Frequencies 45 1MHz First I F 455kHz Second I F Number of Channels 208 Frequency Source PLL Synthesiser Frequency Stab...

Страница 7: ...603 95 Protection against ingress of IEC 529 IP54 dust and water Vibration BS2011 Part 2 1Fc IEC 68 2 6 Part 2 1Fd IEC 68 2 34 Robustness Mil Std 810 F ESD 20kV C MIC 15kV Physical Dimensions 175 W x...

Страница 8: ...the mounting bracket attach bracket to the surface by using the two large Phillips head screws provided 3 Install the radio unit to the bracket using the black screw knobs located on each side of the...

Страница 9: ...n Enables disables optional radio functions also enables scrolling when using the Up Down Selection Buttons 6 Scan Select Button Enables disables Scan functions also toggles between Scan and Priority...

Страница 10: ...nventional modes There are only a few differences in their operation and these are detailed as follows Channel Monitoring While on a Trunked System channel monitoring is performed automatically by the...

Страница 11: ...oon as the message is complete and listen for a response The P T T lever must be pressed continuously while talking and released to listen Receiving 1 Turn power on and set the volume level as previou...

Страница 12: ...ed by observing the LED indicator for a solid yellow color If solid yellow is observed you must wait for the indication to leave before a transmission can be made 5 Press and hold the microphone P T T...

Страница 13: ...press and hold will scroll until button is released All System and Group names will be shown in the display and are preprogrammed by your Dealer Mode Button This button will allow you to return to yo...

Страница 14: ...nce option is shown in display a second key press of OPT will select option to be used under the OPT button indicated by the SCAN icon If no button press is detected option will not be enabled and rad...

Страница 15: ...Public address mode if previously selected as the OPT button function allows the microphone to be used as a public address or intercom feature When activated by a press and release of the OPT button t...

Страница 16: ...The majority of LED indications and audible alerts can be enabled or disabled by your Dealer via programming STATUS DESCRIPTION LED COLOR ICON AUDIBLE TONE DISPLAY Normal Power On Ready Red Yellow Gr...

Страница 17: ...on Two Beeps Scan Modes Your SM5402 Radio may be programmed for one or more scan modes depending upon your Dealer programming LTR Manual Group Scan To enable LTR manual Group scan enter normal scan by...

Страница 18: ...r back on while continuing to hold the scan button Your display will show one of the following EDIT GRP EDIT SYS EDIT PRI Continue holding the scan button until the desired edit function is shown in t...

Страница 19: ...n its received scanned Group After transmission is completed the scan delay time will become active allowing for a call to be immediately returned before scanning resumes Talk Back Scan is enabled by...

Страница 20: ...adio will go back to the selected channel and resume priority look back operation After a scanned call is received the scan wait time will be active allowing you to pick up the microphone and answer t...

Страница 21: ...bers will appear in your radio display will be indicated as P in your display Note The key is normally used to end or hang up an interconnect system Consult your Dealer for exact system operation 3 Pr...

Страница 22: ...memory under that key To Recall a Stored number from Memory 1 Press and release the RCL key 2 Press and release the number key from which a number has been stored 3 Press SND to dial the recalled num...

Страница 23: ...perating manual may not be copied or reproduced without the express written permission of Maxon Furthermore the purchase of Maxon products shall not be deemed to grant either directly or by implicatio...

Страница 24: ...ctionally equivalent reconditioned or new parts or boards Replaced parts accessories batteries or boards are warranted for the balance of the original time period All replaced parts accessories batter...

Страница 25: ...AMAGES INCLUDING ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES OR FOR THE LOSS OF PROFIT REVENUE OR DATA ARISING OUT OF THE USE OF OR THE INABILITY TO USE THE PRODUCT This warranty is void...

Отзывы: