Server Settings
Item
Description
Default
Application Mode
Select from “Transparent” or “Modbus RTU Gateway”.
Transparent: Router will transmit the serial data
transparently
Modbus RTU Gateway: Router will translate the Modbus RTU
data to Modbus TCP data and sent out, and vice versa
Transparent
Protocol
Select from “TCP Client”, “TCP Server”, “UDP” or “Robustlink”.
TCP Client: Router works as TCP client, initiate TCP
connection to TCP server. Server address supports both IP
and domain name
TCP Server: Router works as TCP server, listening for
connection request from TCP client
UDP: Router works as UDP client
Robustlink: Router will automatically upload the serial data
to Robustlink platform under the Robustlink protocol.
Robustlink is a management platform from Robustel. This
function only available when Router is connects to
Robustlink
TCP Client
Server Settings
Item
Description
Default
Server Address
Enter the address of server which will receive the data sent from
router’s serial port. IP address or domain name will be available.
Null
Server Port
Enter the specified port of server which is used for receiving the
serial data.
Null
Local IP @ Transparent
Enter router’s LAN IP which will forward to the internet port of
router.
Null
Local Port @ Transparent
Enter the port of router’s LAN IP.
Null
Local IP @ Modbus
Enter the local IP of under Modbus mode.
Null
Содержание multimax+
Страница 1: ...Dual Port Dual SIM Industrial Cellular Router 4G User Manual 1 04...
Страница 7: ...Multimax_user manual_v 4 0 4 July 11 2018 7 139 Confidential...
Страница 10: ...Multimax_user manual_v 4 0 4 July 11 2018 10 139 Confidential 1 4 Dimensions...
Страница 28: ...Multimax_user manual_v 4 0 4 July 11 2018 28 139 Confidential...
Страница 89: ...Multimax_user manual_v 4 0 4 July 11 2018 89 139 Confidential...
Страница 120: ...Multimax_user manual_v 4 0 4 July 11 2018 120 139 Confidential...