Multimax_user manual_v.4.0.4 July. 11, 2018 55/139
Confidential
Alarm On Action
Digital Output initiates when there is an alarm. Selected from “High”, “Low” or
“Pulse”.
High: a high electrical level output
Low: a low electrical level output
Pulse: Generates a square wave as specified in the pulse mode parameters when
triggered
High
Alarm Off
Action
Digital Output initiates when alarm removed. Selected from “High”, “Low” or “Pulse”.
High: a high electrical level output
Low: a low electrical level output
Pulse: Generates a square wave as specified in the pulse mode parameters when
triggered
Low
Initial State
Specify the Digital Output status when powered on. Selected from “Last”, “High” or
“Low”.
Last: DO’s status will consist with the status of last power off
High: DO interface is in high electrical level
Low: DO interface is in low electrical level
Low
Delay
Set the delay time for DO alarm start-up. The first pulse will be generated after a
“Delay”. Enter from 0 to 30000ms. (0=generate pulse without delay)
0
Hold Time
Set the hold time of DO status (Alarm On Action/Alarm Off Action). When the action
time reach this specified time, DO will stop the action. Enter from 0 to 255 seconds.
(0=keep on until the next action)
0
Low-level Width Set the low-
level width. It is available when enabling Pulse as “Alarm On Action/Alarm
Off Action”. In Pulse Output mode, the selected digital output channel will generate a
10
DO
Item
Description
Default
square wave as specified in the pulse mode parameters. The low level widths are
specified here. Enter from 1 to 30000 ms.
High-level
Width
Set the high-
level width. It is available when enabling Pulse as “Alarm On
Action/Alarm Off Action”. In Pulse Output mode, the selected digital output channel
will generate a square wave as specified in the pulse mode parameters. The high level
widths are specified here. Enter from 1 to 30000 ms.
10
Alarm Source
Digital Outpu
t initiates according to different alarm source. Selected from “DI1
Alarm”, “DI2 Alarm”. DI1/DI2 Alarm: Digital Output triggers the related action when
there is alarm from Digital Input.
DI1
Alarm
Содержание multimax+
Страница 1: ...Dual Port Dual SIM Industrial Cellular Router 4G User Manual 1 04...
Страница 7: ...Multimax_user manual_v 4 0 4 July 11 2018 7 139 Confidential...
Страница 10: ...Multimax_user manual_v 4 0 4 July 11 2018 10 139 Confidential 1 4 Dimensions...
Страница 28: ...Multimax_user manual_v 4 0 4 July 11 2018 28 139 Confidential...
Страница 89: ...Multimax_user manual_v 4 0 4 July 11 2018 89 139 Confidential...
Страница 120: ...Multimax_user manual_v 4 0 4 July 11 2018 120 139 Confidential...