In User Manual
- 34 -
The FTP server, FTP port number, FTP server username and password can all be
configured here.
FTP Sever Host IP/Domain address with Port
User name
Password
Time interval
Header of file name (limit 10 bytes/characters)
Size of file (Bytes) – maximum 102,400 bytes, maximum internal buffer size 10MB
A new file will be created each time the file size is exceeded.
Time stamp – enable (1) or disable (0) timestamp prefix (in seconds)
Each file will have a standard prefix used here with a suffix in the format
DDMMYYYHHMMSS, where D is day, M is month, Y is year, H is hour in 24 hour format, M is
minutes, and S is seconds. E.g. DHMAX10102014181146.csv.
A reboot is required when enabling, disabling or making changes to the FTP options.
The "size of file" parameter is used for limiting the file size of the csv file. All the input from
serial port will be saved in the .csv file, and once the file size of that csv file exceed the
size limit, another file will be created to hold the input. The value allowed is 1000 -
100*1000 Bytes.
Based on the configuration, the file could be uploaded to server periodically. For
example: