![Maxon EPOS4 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/maxon/epos4/epos4_communications-manual_1745152044.webp)
EtherCAT Communication
Integration of ESI Files
EPOS4 Communication Guide
4-44
CCMC | 2019-11 | rel8759
Table 4-18
EtherCAT communication – ESM control register
4.3
Integration of ESI Files
SDOs are used to access the object dictionary. The corresponding interface is CoE. The EPOS4 is
described with an XML file bearing the so-called ESI (EtherCAT Slave Information).
For in-detail description and examples on integration into the EtherCAT master environment
separate
document «EPOS4 Application Notes», chapter “EtherCAT Integration”.
4.4
Error Code Definition
For in detail information on error codes, device-specific errors, and error handling methodology
separate
document «EPOS4 Firmware Specification», chapter “Error Handling”.
Parameter
Address
Bit
Description
Control
0x0120
3…0
0x01: Init Request
0x02: Pre-Operational Request
0x03: Bootstrap Mode Request
0x04: Safe-Operational Request
0x08: Operational Request
Error Acknowledge 0x0120
4
0x00: No error acknowledgment
0x01: Error acknowledgment at rising edge
Reserved
0x0120
7…5
—
Application-specific 0x0120
15…8
—