![Maxon EPOS4 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/maxon/epos4/epos4_communications-manual_1745152011.webp)
USB & RS232 Communication
EPOS4 USB & RS232 Command Reference
EPOS4 Communication Guide
CCMC | 2019-11 | rel8759
2-11
2.1.3
General CAN Commands
2.1.3.1
SendLSS
Send a LSS master message to the CAN bus.
2.1.3.2
ReadLSS
Read a LSS slave message from the CAN bus.
Note that a LSS slave message can be read only if a SendLSS command has been executed before.
Request Frame
OpCode
BYTE
0x7A
Len
BYTE
4
Parameters
BYTE[8]
LSS master message
Response Frame
OpCode
BYTE
0x00
Len
BYTE
2 (number of words)
Parameters
DWORD
“Communication Error Code Definition” on page 6-47
Request Frame
OpCode
BYTE
0x7B
Len
BYTE
2
Parameters
WORD
Timeout [ms]
Response Frame
OpCode
BYTE
0x00
Len
BYTE
6 (number of words)
Parameters
DWORD
“Communication Error Code Definition” on page 6-47
BYTE[8]
LSS slave message frame data