Specifications
Limitations
maxon motor control
2-12
Document ID: rel6852
EPOS4 Positioning Controller
Edition: May 2017
EPOS4 50/5 Hardware Reference
© 2017 maxon motor. Subject to change without prior notice.
2.2.2
Power Dissipation and Efficiency
Figure 2-3
Power dissipation and efficiency
2.3
Limitations
Table 2-5
Limitations
Protection functionality
Switch-off threshold
Recovery threshold
Undervoltage
8.0 V
8.5 V
Overvoltage
58 V
56 V
Overcurrent
20 A
—
Thermal overload
100 °C
90 °C