background image

1- INTRODUCTION

2- WARNINGS

Producer-manufacturer or importer firms’ title, address, and telephone number 

Manufacturer Firm:

MAVILI ELEKTRONIK TICARET VE SANAYI A.S.

SERIFALI MAHALLESI, KUTUP SOKAK NO: 27/1-2-4 UMRANIYE - ISTANBUL - TURKEY

TEL:  +90 216 466 45 05 - +90 216 466 45 10

Service stations’ communication information that related spare parts have been provided

Authorized Services: 

MAVILI ELEKTRONIK TICARET VE SANAYI A.S.

SERIFALI MAHALLESI, KUTUP SOKAK NO: 27/1-2-4 UMRANIYE - ISTANBUL - TURKEY

TEL:  +90 216 466 45 05 - +90 216 466 45 10

TEKSIS TEKNIK ELEKTRONIK SIS. TIC. VE SAN. LTD. STI. 

SERIFALI MAHALLESI, KUTUP SOKAK NO: 27/3 UMRANIYE - ISTANBUL - TURKEY

TEL:  +90 216 313 60 60 - +90 216 313 47 49

Expected operation life which has been determined and announced by related ministry.

This device’s expected operation life is 7 years. 

Maxlogic ML-221XX series conventional fire alarm control panel has, 2, 4, 8, 12 ve 16 zones (detection circuits) according to model 

with 24V DC operating voltage. Power supply of panel has an automatic battery charger and charger control circuit. Fire and fault 

conditions for each zone are indicated by individual LEDs on the fascia. Zone circuits and sounder outputs are continuously 

supervised for open and short circuits. Zones can be put into Test or Disable Mode.

The panel has one sounder output, fire and fault relay outputs and one auxiliary power supply output for energising external 

equipment.

The control unit contains static-sensitive high quality electronic control equipment. Do not use the panel before reading this 

manual. 

The subjects that should be noticed during handling and transportation

•  This product should be stored as packed on indoor areas. 

•  Storing ambient temperature should be (-30°C) to (+60°C), and relative humidity should not be exceed %95 as uncondensed. 

•  Product’s transportation can be performed as packed by train, road, ship and air vehicles.  

•  Transportation ambient temperature should be (-30°C) to (+60°C).

•  The boxes that contain this device should be placed safely and properly to prevent any damage by each other. 

Page 3/16

KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual                                                                                                                   

Warnings that may dangerous or harm people’s or environment’s health during operation

•  MP-8 Panel’s main supplied power is 230V AC. Do not make connections under power to the danger of electric shock

•  Ground connection must be made of the panel definitely.

•  Please consider there are some electronic components inside this device, so do not clean this device by dry rag etc 

The subjects related with maintenance, fixing or device’s cleaning operations that the customer/user has been done on their own

The following points should be checked each working day by user. Observed malfunctions should be registered, and corrective 

activities which were related with these problems should be performed as soon as possible. 

•  If device shows its tranquility condition or if there is a deviation from tranquility condition and authorized service has been 

informed if needed. 

•  When required operations have been performed to alarms which have been registered after last operation day.

•  If disable, experiment or silence operations have been occurred and system turned back to normal operation mode.

Содержание ML-221XX series

Страница 1: ...COMMISSIONING OPERATING AND MAINTENANCE MANUAL MODEL MAXLOGIC SERIES SUB MODEL CONVENTIONAL SYSTEM FIRE ALARM CONTROL PANEL...

Страница 2: ...tions Santral Models Accessories and Options Annex A Panel Wiring Diagram Annex B Panel Dimensions Annex C1 Panel Serigraphy Annex C2 Panel Serigraphy Annex C3 Panel Serigraphy Annex C4 Panel Serigrap...

Страница 3: ...nt Do not use the panel before reading this manual The subjects that should be noticed during handling and transportation This product should be stored as packed on indoor areas Storing ambient temper...

Страница 4: ...in all mounting positions Panel cable entries from back and top of the panel are available for easy mounting Drill and plug the wall then fix the cabinet using all fixing points Open the panel front c...

Страница 5: ...Illumination indicates any fault condition This would typically be Mains power supply or battery voltage is low Leak from or wire to earth Open or short circuit on the sounder circuit Open or short c...

Страница 6: ...load a short circuit or exceeding 230V AC on mains supply input On activation of the mains fuse the batteries energise the panel 9 1 NORMAL In normal condition only the Power On LED should illuminate...

Страница 7: ...are as follows Set the Button Control key to Enable position The buzzer will sound once Press the Silence Buzzer button then keeping the button pressed press the Reset button till Alarm Buzzer Silence...

Страница 8: ...etwork card Memory card Network Memory card 4 way relay card 4 way sounder card 2 way relay card 2 way sounder card 2 4 8 16 Zone Capacity Product Code Product Name Page 8 16 KK 642 042 Rev No 0 01 11...

Страница 9: ...Y 2213 Memory card provides to save event logs for ML 221XX series panels Up to 1000 event log memory It provides to monitor log events in the PC program Providing panel configuration via PC program 1...

Страница 10: ...Page 10 16 KK 642 042 Rev No 0 01 11 12 ML 221XX User Manual Network Card MLY 2212 Mermory Card MLY 2213 Network and Memory Card MLY 2214 Wiring Diagram...

Страница 11: ...Page 11 16 KK 642 042 Rev No 0 01 11 12 ML 221XX User Manual Annex A Panel Wiring Diagram...

Страница 12: ...Page 12 16 KK 642 042 Rev No 0 01 11 12 ML 221XX User Manual Annex B Panel Dimensions 400mm 300mm 100mm...

Страница 13: ...Page 13 16 KK 642 042 Rev No 0 01 11 12 ML 221XX User Manual Annex C1 Panel Serigraphy...

Страница 14: ...Page 14 16 KK 642 042 Rev No 0 01 11 12 ML 221XX User Manual Annex C2 Panel Serigraphy...

Страница 15: ...Page 15 16 KK 642 042 Rev No 0 01 11 12 ML 221XX User Manual Annex C3 Panel Serigraphy...

Страница 16: ...Page 16 16 KK 642 042 Rev No 0 01 11 12 ML 221XX User Manual Annex C4 Panel Serigraphy...

Отзывы: