© Copyright 2019. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: [email protected]
Page: 4
REV: 12/19/19
Mount Accessories
Ceiling:
1.
Use the four M8 expansion bolts to fix the bracket to the ceiling.
2.
Use the six M4 hexagon socket screws with a torque value
of
3 N-m
in order to fix the driver cavity cover to the bracket.
3.
Lights should be hung on the driver cavity cover; connect wires
accordingly.
4.
Use the three M5 socket head screws with torque value of
5 N-m
to the fixture.
Stanchion 25° / Stanchion 90°:
1.
Screw the bracket into the pole and tighten the M5 fastening
screws.
2.
Use the six M4 hexagon socket screws to fix the tank cover
to the bracket with a torque value of
3 N-m
.
3.
Connect electrical components.
4.
Use the three M5 socket head screws to fix the luminaire with
a torque value of
5 N-m
.
M4 Socket head cap screws
(Washers induded) M8
Expansion bolts
step1
step2
M4
step3
step4
M5
Socket head cap screws
Screws
M5
step1
step2
step3
step4
M5
Socket head cap screws
M4
Socket head cap screws
Operating Instructions
Hazardous Location HLRS Series
MaxLite Hazardous Location HLRS Series
®