MECHANICAL SPECIFICATIONS 

ELECTRICAL SPECIFICATIONS

•  24 Volt DC motor 

•  Two independently adjustable closing speed controls with 16 positions each

•  Switchable 115/230 voltage selection

•  Adaptive DSP motor control for advanced motion control 

•  Real time performance analyzer and event log (OBD PORT and Black Box)

•  Magic Box enables low voltage wiring capabilities for remote power up to 1000 ft 

•  On-board switch for solar mode enables 5 milliamp idle in sleep mode

•  Gold contact input connections and automobile grade connectors

•  -4F to 165F (-20C to +74C) operational range including battery backup without a heater

•  Shipping weight of Actuator: Super Arm 1300  (25 lbs)

•  Shipping weight of AC Control Box  (38 lbs)

•  The patented brake system allows the operator to retract with extreme force. When the force 

exceeds 2 tons, the clutch releases upon impact, then automatically resets. Causes for clutch 

release include a vehicle strike while the gate is in motion.

•  Stainless steel output shaft - 1 1/4”

•  Direct gear drive (no internal chains, belts, or pulleys)

•  Mechanical and electrical gate release functions

•  Continuous duty cycle at extreme temperature range. No overheating

•  Intelligent ramp-up and ramp-down for smooth gate operation

MAX SUPER ARM 1300 

FEATURE LIST:

   

=

 

Unique to Max SUPER ARM 1300

100

75

C

min 955 – 

C

max 1450

min 995 – max 1490

58

116 58

115

40

30

70

380

65

180

100

37

7.3”

Min = 37”

4.5”

9.25”

Max = 54.75”

control box

13.5”

5.75”

17”

JOG GATE
OPEN / CLOSE

RESET ALARM

115VAC

3A max

7A

FUSE

POWER

On

Off

WARNING:  For continued protection 

against fire, replace only with the 

same type and rating of fuse.

AVERTISSEMENT:

 pour ne pas compromettre la 

protection contre les risques d’incendie, utiliser un 

fusible de mêmes type et caractéristiques nominales.

Select Input Voltage
115VAC or 230VAC  

(AC)

POWER IN

115V

SAFETY

CENTER

EXIT

J3

J2

J4

J5

EXIT PWR

ALARM

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

MOTOR 2

MOTOR 1

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

MOTOR

OVER

LOAD

ERD

MOTOR

OVER

LOAD

MIN

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2

LIMITS

MAG

LOCK

UL

ENTRAP

STOP

CLOSE

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

BATTERY

INPUT

ERROR

BATTERY

IN USE

POWER

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

E

F

1/2

RESET

ID

PLUG

MODULE

PORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NC
OPEN / CLS NC

GND

12VDC OUT

GND

GND

GND

GND

GND

JO

CL

OS

E

JO

OP

EN

TAMPER IN

TAMPER NO

GATE DISABLE

KEYPAD/CARD

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE COM

COM

STOP

OPEN

PHOTO CLS 10K
OPEN / CLS 10K

12VDC OUT

NO

COM

NC

COM

GATE CLOSED

LIMIT 1

GND

LIMIT 2

MOTOR 1

LIMITS

MOTOR 1

MOTOR 2

LIMIT 1

GND

LIMIT 2

LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2

ID PLUG

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOP

LOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFF

BATTERY

CLOSE

DUAL

ON

ANTI-

TAILGATE

PUSH

OPEN

PULL

OPEN

GATE

OFF

1

2

3

4

5

6

7

8

9

10

OFF

1

2

3

4

5

6

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

FAULTS

OPERATOR

DSP ARM CONTROLLER

OFF

EXIT LOOP

16

MIN

16

MIN

3

1

14

12

9

7

3

1

14

12

9

7

UL SENSOR 10

K

UL SENSOR N.C.

MODE 

A

MODE B

PROGRAM

MOTOR 1

INPUTS

[+]

[-]

[+]

[-]

MOTOR 2

INPUTS

MAXIMUM CONTROLS

DSP ARM CONTROLLER

8ft 10ft 12ft

1300 lbs

800 lbs

600 lbs

Max Weight/

Length

Gate Capacity

2

Содержание MAX SUPER ARM 1300

Страница 1: ...rator Overload clutch release on 2 ton impact 2 Year Warranty or 100 000 Cycles whichever comes first Max cloud app DSP controlLer UL 2018 THE NEW STANDARD Rev 1 3_ April 29 Timers Diagnose Users Settings GATE STATUS OPEN OPENING CLOSED CLOSE OPEN LAGUNA WOODS GATE GATE RELEASE ...

Страница 2: ...f Actuator Super Arm 1300 25 lbs Shipping weight of AC Control Box 38 lbs The patented brake system allows the operator to retract with extreme force When the force exceeds 2 tons the clutch releases upon impact then automatically resets Causes for clutch release include a vehicle strike while the gate is in motion Stainless steel output shaft 1 1 4 Direct gear drive no internal chains belts or pu...

Страница 3: ...ies provide 500 cycles in case of power failure with three modes of battery backup open once leave open or leave closed On board three button station On board UL reset button Unique to Max SUPER ARM 1300 SECURITY SPECIFICA TIONS High traffic intuitive loop management system for exceptional security Advanced security features with built in audible and remote alarms Magnetic lock control relay outputs...

Страница 4: ...t Passes for visitors With Max Keypad option Program keypad keycodes Wiegand keycodes for card readers radio receivers and transponders with time restrictions Setup Auto Open Close Timer for Max operators Retrieve Event log Retrieve Operator Diagnostics info Error log Sa fet y Loop c l o s e o p e n JOG GATE OPEN CLOSE RESET ALARM Sa fet y Loop c l o s e o p e n JOG GATE OPEN CLOSE RESET ALARM Mov...

Страница 5: ...he key and lift up the hood To engage the actuator push down the hood and lock to resume automatic operation The Max SUPER ARM 1300 ships with a heavy duty half inch stock rear bracket that is broached and welded Both brackets front and rear are silver zinc plated P Front Bracket Rear Bracket MOUNTING BRACKETS 5 MECHANICAL RELEASE ...

Страница 6: ...SUPER ARM 1300 will collapse on impact when struck by vehicular traffic When a vehicle hits a moving gate to avoid damage to the actuators the SUPER ARM 1300 reset automatically VEHICLE HIT PROTECTION PUSH OPEN PULL OPEN INSIDE PROPERTY OUTSIDE PROPERTY TWO INST ALLA TION OPTIONS OPEN OPEN CLOSED CLOSED 6 ...

Страница 7: ...g gate leaves can be synced ASYMMETRIC SPEED CONTROL For asymmetric installations the two independent closing speeds can be adjusted to achieve a smooth closing sync Whichever gate closes first slow it down This enables the installer to visually sync the closing cycle This feature is unique to Maximum Control s actuators 7 ...

Страница 8: ... zinc plated and powder coated for corrosion resistance The Max AC Control Box comes with an exterior UL reset button a convenient jog key switch for emergency access or egress a 10 amp power supply with two 115 VAC accessory outlets two 7 amp batteries conveniently located behind the control panel a loop rack and much more A lockable steel cover finishes off this slick design A convenient LCD disp...

Страница 9: ...OPTIONAL ON and OFF Power Supply Switch 30A FUSE Loop Rack OPTIONAL Steel housing 2 layer protection Gold zinc Electrostatic powder coating Gold plated automobile connectors through the system Control Panel Solar Regulator 24V 20A MORNING STAR Solar Regulator 24V 20A MORNING STAR 9 ...

Страница 10: ...ry Backup Mode Switch 2 Battery Test Switch 3 ERD Sensitivity 4 OBD Port 5 DIP Switches 6 Program Button 7 Loop Status 8 Solar Mode Application 9 Motion Control Buttons 10 Maglock Delay 11 LCD Display 12 Close Timer Switch 13 Jog Open Close 14 Closing Gate Speed 8 7 6 5 3 4 2 1 CONTROL FEA TURES AND CONNECTIONS 1 2 11 3 4 5 6 7 8 9 12 10 14 13 10 ...

Страница 11: ...er coating Gold plated automobile connectors through the system SOLAR MODE Switch to enable low power draw for solar mode Control Panel Solar Regulator 24V 10A MORNING STAR Solar Regulator 24V 10A MORNING STAR 24V Solar Panel Output 36 V Max Open Circuit Wire solar panel terminals to solar regulator input Caution polarity matters Solar Panel POWE SOLAR Neg ON and OFF Power Supply Switch ...

Страница 12: ...0 11 12 4 5 15 16 17 8 9 2 2 20 14 16 7 8 1 1 40 9 10 2 3 NUM NUM 60 4 5 NUM NUM NUM NUM 5 97 173 58 105 24 44 15 92 169 54 101 21 41 20 90 166 53 99 19 39 100 59 131 25 67 NUM 13 250 9 68 NUM 14 NUM NUM Gate solar cycles per day Zone 1 6 Hrs Sunlight Day Zone 2 4 Hrs Sunlight Day Zone 3 2 Hrs Sunlight Day Solar Panel Must Use 24V lar Panel Solar Panel Must Use 24V lar Panel Total System Current D...

Страница 13: ...s loop inputs power inputs relay outputs and all communication lines over 35 channels of protection in 1 1 000 000 000 of a second With special emphasis on power supply protection the Max SUPER ARM 1300 is guaranteed to withstand any lightning hit more than 50 feet away Truly protected like no other operator in the world 50 FEET 50 FEET 50 FEET 50 FEET 13 ...

Страница 14: ...ion mismatch e Damages due to vandalism Section III RMA Shipping Policy a Maximum Controls LLC will pay for return shipping via standard ground UPS or USPS FOB CA on all RMA s within one year of Distributor s purchase b Any form of Expedited Shipping on any RMA will be paid by Distributor Section IV Product Returns a Products must be in original resalable condition with all warranty information ma...

Страница 15: ... 949 699 0220 10530 Lawson River Ave Fountain Valley CA 92708 USA Independent Dealer or Distributor www Max US com DSP Control AC AC control control box box MADE IN USA MAX MAX SUPER ARM SUPER ARM 1300 1300 MADE IN GERMANY ...

Отзывы: