MECHANICAL SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
• 24 Volt DC motor
• Two independently adjustable closing speed controls with 16 positions each
• Switchable 115/230 voltage selection
• Adaptive DSP motor control for advanced motion control
• Real time performance analyzer and event log (OBD PORT and Black Box)
• Magic Box enables low voltage wiring capabilities for remote power up to 1000 ft
• On-board switch for solar mode enables 5 milliamp idle in sleep mode
• Gold contact input connections and automobile grade connectors
• -4F to 165F (-20C to +74C) operational range including battery backup without a heater
• Shipping weight of Actuator: Super Arm 1300 (25 lbs)
• Shipping weight of AC Control Box (38 lbs)
• The patented brake system allows the operator to retract with extreme force. When the force
exceeds 2 tons, the clutch releases upon impact, then automatically resets. Causes for clutch
release include a vehicle strike while the gate is in motion.
• Stainless steel output shaft - 1 1/4”
• Direct gear drive (no internal chains, belts, or pulleys)
• Mechanical and electrical gate release functions
• Continuous duty cycle at extreme temperature range. No overheating
• Intelligent ramp-up and ramp-down for smooth gate operation
MAX SUPER ARM 1300
FEATURE LIST:
=
Unique to Max SUPER ARM 1300
100
75
C
min 955 –
C
max 1450
min 995 – max 1490
58
116 58
115
40
30
70
380
65
180
100
37
7.3”
Min = 37”
4.5”
9.25”
Max = 54.75”
control box
13.5”
5.75”
17”
JOG GATE
OPEN / CLOSE
RESET ALARM
115VAC
3A max
7A
FUSE
POWER
On
Off
WARNING: For continued protection
against fire, replace only with the
same type and rating of fuse.
AVERTISSEMENT:
pour ne pas compromettre la
protection contre les risques d’incendie, utiliser un
fusible de mêmes type et caractéristiques nominales.
Select Input Voltage
115VAC or 230VAC
(AC)
POWER IN
115V
SAFETY
CENTER
EXIT
J3
J2
J4
J5
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING
CLOSING
MOTOR 2
MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP
CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E
F
1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JO
G
CL
OS
E
JO
G
OP
EN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE COM
COM
STOP
OPEN
PHOTO CLS 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF
2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14
12
9
7
3
1
14
12
9
7
UL SENSOR 10
K
UL SENSOR N.C.
MODE
A
MODE B
PROGRAM
MOTOR 1
INPUTS
[+]
[-]
[+]
[-]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
8ft 10ft 12ft
1300 lbs
800 lbs
600 lbs
Max Weight/
Length
Gate Capacity
2