RM350
INSTALLATION AND COMMISSIONING
RM350 GAS CONTROLLERS
MAY 16
13 of 18
Overload
This signal is used for safety and the controller will show an overload alarm in the status page if the
overload trips out on the hydraulic power pack.
GAS Controlle
r
Injection Moulding Machine
NOTE
:
All connections must be volt free at
IMM.
Suggested Connections IMM:
Overload auxiliary contact
Oil Temperature
This signal is used for safety and the controller will show an oil temperature alarm in the status page if
the oil temperature goes above its set level..
GAS Controlle
r
Injection Moulding Machine
NOTE
:
All connections must be volt free at
IMM.
Suggested Connections IMM:
Temperature switch
Oil Level
This signal is used for safety and the controller will show an oil level alarm in the status page if the oil
level falls below its minimum set point.
GAS Controlle
r
Injection Moulding Machine
NOTE
:
All connections must be volt free at
IMM.
Suggested Connections IMM:
Level switch
Pressure Bypass
This signal is used to actuate the pressure bypass solenoid on the external hydraulic power pack.
GAS Controlle
r
Injection Moulding Machine
NOTE
:
All connections must be volt free at
IMM
.