Register Name:
SU.RFRC
Register Description:
Receive Frame Rejection Control
Register Address:
15Eh
Bit
# 7 6 5 4 3 2 1 0
Name — UCFR
CFRR
LERR
CRCERR
DBR
MIIER
BFR
Default
0 0 0 0 0 0 0 0
Bit 6: Uncontrolled Control Frame Reject (UCFR).
When set to 1, Control Frames other than Pause Frames
are allowed. When this bit is equal to zero, non-pause control frames are rejected.
Bit 5: Control Frame Reject (CFRR).
When set to 1, control frames are allowed. When this bit is equal to zero,
all control frames are rejected.
Bit 4: Length Error Reject (LERR).
When set to 1, frames with an unmatched frame length field and actual
number of bytes received are allowed. When equal to zero, only frames with matching length fields and actual
bytes received will be allowed.
Bit 3: CRC Error Reject (CRCERR).
When set to 1, frames received with a CRC error or MII error are allowed.
When equal to zero, frames with CRC or MII errors are rejected.
Bit 2: Dribbling Bit Reject (DBR).
When set to 1, frames with lengths of non-integer multiples of 8 bits are
allowed. When equal to zero, frames with dribbling bits are rejected. The dribbling bit setting is only valid only if
there is not a collision or runt frame.
Bit 1: MII Error Reject (MIIER).
When set to 1, frames are allowed with MII Receive Errors. When equal to zero,
frames with MII errors are rejected.
Bit 0: Broadcast Frame Reject (BFR).
When set to 1, broadcast frames are allowed. When equal to zero,
broadcast frames are rejected.