Reverse Control Channel
The serializer uses the reverse control channel to receive
I
2
C/UART, MS, and GPO signals from the deserializer in
the opposite direction of the video stream. The reverse
control channel and forward video data coexist on the
same serial cable forming a bidirectional link. The reverse
control channel operates independently from the forward
control channel. The reverse control channel is available
2ms after power-up. The serializer temporarily disables
the reverse control channel for 500µs after starting/stop
-
ping the forward serial link.
Figure 23. Stereo I
2
S (24-Bit Samples, Padded with Zeros)
Figure 24. Stereo I
2
S (16-Bit Samples, No Padding)
32 SCK
WS
SCK
SD
64 SCK
LEFT CHANNEL
MSB 24-BIT DATA
LSB 8 BITS ZERO
RIGHT CHANNEL
WS
SCK
SD
32 SCK
LEFT CHANNEL
16-BIT DATA
RIGHT CHANNEL
16 SCK
MAX9277/MAX9281
3.12Gbps GMSL Serializers for Coax or
STP Output Drive and LVDS Input
www.maximintegrated.com
Maxim Integrated │
33