Trust Protection Unit (TPU)
11.2 Modular Arithmetic Accelerator (MAA)
Field
Bits
Default
Access
Description
ocalc
4
0
R/W
Optimized Calculation Control
• 0: No optimization is used
• 1: Skip unneeded multiply operations
MAA_CTRL.if_done
Field
Bits
Default
Access
Description
if_done
5
0
R/W
Interrupt Flag - Calculation Done
Write to 0 to clear.
This bit is set to 1 by hardware when an MAA operation has completed successfully.
MAA_CTRL.inten
Field
Bits
Default
Access
Description
inten
6
0
R/W
MAA Interrupt Enable
• 0: MAA Interrupts are disabled
• 1: MAA Interrupt can be triggered on MAA calculation completed or error conditions.
MAA_CTRL.if_error
Field
Bits
Default
Access
Description
if_error
7
0
R/W
Interrupt Flag - Error
Rev.1.3 April 2015