OPERATING INSTRUCTIONS
4-7
1.2
Push start button, the controller monitor will show
PrE
.
1.3
Push stop button again. The controller monitor will show currently inside drum
temperature such as 32 °C.
1.4
Push the UP and DOWN button at same time then the beep louder twice time.
1.5
The controller monitor will display
CY 01
again that means ready for start operating.
1.6
If the machine can not start after pressed start button and the controller monitor have
shown
PrE
. Please go back to Item 1.1.
SETUP MODE
The setup options are programmable options that are in operation during all wash cycles.
The options are:
Temperature displayed in degrees Celsius or Fahrenheit.
Spray Rinse and Supply 4 enabled
Auxiliary heat and Spray Rinse enabled
Auxiliary heat and Supply 4 enabled
Advance function
Coast down delay timer function
Take note that these options can only be changed while in Setup mode.
Temperature Display
This setup option affects the display and programming of all temperatures.
cEL
selects
programming/display in degrees Celsius, while
FRr
. selects degrees Fahrenheit. The UP and
DOWN keys toggle between the two settings. The Start key accepts the selection and moves you to
the next setup option.
Spray Rinse, Supply 4, and Auxiliary Heading
This setup option allows you to select among the following options:
Spray Rinse and Supply 4 enabled
Auxiliary heat and Spray Rinse enables
Auxiliary heat and Supply 4 enables
To enable
Spray Rinse
and
Supply 4
, use the up and down key to see
Srin
. When this
option is selected, Spray Rinse and Supply 4 are enabled, as well as Supply 7 (Supply 3 and Supply
4 combined). This is the default setting. When this option is selected, no further programming in
Setup is possible. Press the Stop key to exit Setup.
To enable
Spray Rinse
and
Auxiliary Heating,
use the up or down key to see
heat
instead
of
Srin
, as above. Now press the Start key (enter). Now use the up or down key to see
Srin
. Press
the start key (enter). No
Further Setup programming is possible. Press the Stop key exit Setup.
To enable
Auxiliary Heat
and
Supply 4,
press the Up or Down key to see
hEAt.
Press the
start key (enter). Now press the Up or Down key to see
SUP4
. Press the Start key to select, and
press the Stop key to save and exit Setup mode. This is the default mode for machines without
Spray Rinse.
Содержание MWHE20
Страница 1: ......
Страница 12: ...SPECIFICATION COMPONENT IDENTIFICATION 2 3 C B ...