INSTALLATION PROCEDURES
3-1
SECTION 3
INSTALLATION PROCEDURES
3.1
DIMENSIONL CLEARANCES
When installing the washer – extractor, it is important to allow adequate clearance on all
sides of the machine. When multiple machines are installed, it is important to allow for the specified
minimum clearances between machines. The following Table 3-1 shows recommended minimum
clearances for the various freestanding models.
NOTE:
The dimensions are approximate and subject to normal manufacturing tolerances.
If exact dimensions are required for construction purposes, request certified
drawings from the factory. We reserve the right to make changes at any time
without notice.
Table 3-1
Minimum service clearances
Detail
Unit
HARDMOUNT Series
Metric
US
Recommended
Minimum
(A)
Minimum rear clearance
mm.
inch
760
30
305
12
(B)
Minimum clearance between machine
and wall
mm.
inch
455
18
25
1
(C)
Minimum clearance between machines
mm.
inch
455
18
25
1
(D)
Minimum font clearance
mm.
inch
838
33
838
33
Fig. 3-1
Dimensions
for
construction
Содержание MWHE20