background image

20

21

MAXDATA PLATINUM 520 Server

Server Board Installations and upgrades

20

21

MAXDATA PLATINUM 520 Server

Server Board Installations and upgrades

1.  Observe the safety and ESD precautions above and at the end of this book. See “Installation 

Precautions”.

2.  Turn off all peripheral devices connected to the server. Turn off the server.
3.  Remove power from your system by unplugging the AC power cord.
4.  Remove the chassis cover. See your chassis documentation for instructions.
5.  Locate the battery. See Figure 8.
6.  Gently pull back on the metal tab to release the battery.
7.  Remove the battery from its socket.

8.  Dispose of the battery according to local ordinance.
9.  Remove the new lithium battery from its package, and, being careful to observe the correct 

polarity, insert it in the battery socket.

10. Reconnect or replace any internal components you needed to disconnect or remove. 
11. Replace the server’s cover. Reconnect any external components you needed to disconnect.
12. Attach the AC power cord.
13. Run Setup to restore the configuration settings to the RTC.

TP00685

 

Figure 8.  Replacing the Battery

Содержание PLATINUM 520

Страница 1: ...System Manual MAXDATA PLATINUM 520 Server ...

Страница 2: ...2 Contents 2 Contents ...

Страница 3: ... Replacing the Processor 17 Installing the Processor 17 Removing the Processor 19 Installing a PCI Card 19 Replacing the Backup Battery 20 4 Server Utilities 23 BIOS Setup 23 Clearing the CMOS 24 Clearing the Password 24 LED Information 25 BIOS Error Messages 26 BIOS POST Beep Codes 27 BIOS Recovery Beep Codes 28 5 Regulatory and Integration Information 29 Product Regulatory Compliance 29 Product ...

Страница 4: ...ing Socket Lever and Attaching Processor 17 7 Installing Heat Sink over Processor 18 8 Replacing the Battery 21 Tables 1 NIC LEDs 6 2 Server Board Features 9 3 Configuration Jumper J17 12 4 BIOS Select Jumper J29 12 5 Keyboard Commands 23 6 Keyboard Commands 25 7 BIOS Error Messages 26 8 Beep Codes 27 9 BIOS Recovery Beep Codes 28 10 Product Certification Markings 29 ...

Страница 5: ...d disks or to a floppy disk they are stored as magnetic information on the media Make sure that they are not damaged by magnetic or electromagnetic fields Because the electronics in your computer can be damaged by jarring no mechanical devices should be placed on the same surface as the server This is especially important for impact printers whose vibrations could damage the hard disk Please take ...

Страница 6: ...d left of each NIC provide the following information Table 1 NIC LEDs NIC LED Color LED State Description NIC1 Gigabit Left LED Off No network connection Solid Amber Network connection in place Blinking Amber Transmit receive activity Right LED Off 10 Mbps connection if left LED is on or blinking Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection TP00682 H G E A C F B D Figure 1 Back...

Страница 7: ...se you can find the neccessary controls like power button reset button and the HDD Leds Press the power button one time briefly in order to boot the server A Power switch E NIC1 LED B Reset switch F NIC2 LED C Disable Fan Warning G HDD LED D Fan Warning LED H Power LED Figure 2 The Controls A B C H G F E D ...

Страница 8: ...8 Server Board Features 8 Server Board Features ...

Страница 9: ... I O Control National PC87427 I O controller chip Peripheral Interfaces Two external USB 2 0 ports on the back panel with an additional internal header that provides support for two additional USB ports for support at the front of the chassis four total possible USB 2 0 ports One serial port and one serial port header Two ATA interfaces with Ultra 33 66 and 100 DMA mode Two serial ATA connectors w...

Страница 10: ...ort for SMBIOS Power Management Support for ACPI Wake on USB PCI RS 232 PS 2 LAN and control panel Server Management Intel Server Management 8 0 support via the National Semiconductor PC87431M integrated management controller providing onboard plat form instrumentation Leadership Technologies Intel Light Guided Diagnostics on some FRU devices processors power Port 80 Diagnostic LEDs displaying POS...

Страница 11: ...System Fan Header 4 I Auxiliary Power Connector CC Front Panel Connector J System Fan Header 1 DD SATA Backplane Header K Main Power Connector EE Front Panel USB Header L DIMM Sockets labeled from the top 1B 1A 2B 2A FF OEM Remote Management Card Connector M 12 V CPU Power Connector GG LCD Header N Processor Socket 1 HH SATA B1 B2 B3 B4 Connectors optional O Processor 1 Fan Header II Battery P Pro...

Страница 12: ...nly used when the BIOS has become corrupted These pins should be jumpered on 9 10 for normal operation Table 4 BIOS Select Jumper J29 Operation Pins What happens at System Reset Normal Boot 1 2 If these pins are jumpered the board will boot off of either BIOS bank 0 or bank 1 depending on which is available first Force Boot 2 3 If these pins are jumpered the board will boot off of bank 0 BIOS TP00...

Страница 13: ...e minimum memory configuration is one DIMM installed in DIMM socket 1B the socket farthest from the processors However for optimum performance and dual channel interleave operation a minimum of two DIMMs should be installed DIMMs on channel A are paired with DIMMs on channel B to configure 2 way interleaving Both DIMMS in Bank 1 DIMM1B and DIMM1A must be populated before any DIMMs are installed in...

Страница 14: ...14 Server Board Installations and upgrades 14 Server Board Installations and upgrades ...

Страница 15: ...he silkscreen on the board for the DIMMs displays DIMM1B DIMM1A DIMM2B and DIMM2A starting from the inside of the board DIMM2A is the socket closest to the processor socket Installing DIMMs To install DIMMs follow these steps 1 Observe the safety and ESD precautions at the end of this manual See Installation Precautions 2 Turn off all peripheral devices connected to the server Turn off the server ...

Страница 16: ...nnect or remove 12 Replace the server s cover Reconnect any external components you needed to disconnect 13 Attach the AC power cord Removing DIMMs To remove a DIMM follow these steps 1 Observe the safety and ESD precautions at the end of this manual See Installation Precautions 2 Turn off all peripheral devices connected to the server Turn off the server 3 Remove the AC power cord from the server...

Страница 17: ...discharge ESD damage to the processor by doing the following 1 Touch the metal chassis before touching the processor or server board Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor 2 Avoid moving around unnecessarily Installing the Processor 1 Observe the safety and ESD precautions at the end of this manual See Installation Preca...

Страница 18: ... 7 letter A Your heat sink style may vary 9 Finger tighten each captive screw working around the heat sink Tighten the screws evenly Do not fully tighten one screw at a time Continue to gradually and evenly tighten each screw working around the heat sink See Figure 7 letter B 10 Server Chassis SC5275 E only Connect the heat sink fan cable to the processor fan connector 11 Reconnect or replace any ...

Страница 19: ...e processor lever 10 Remove the processor 11 Reconnect or replace any internal components you needed to disconnect or remove 12 Replace the server s cover Reconnect any external components you needed to disconnect 13 Attach the AC power cord Installing a PCI Card The PCI slots support full height add in cards or low profile PCI add in cards with a standard full height PCI mounting bracket 1 Observ...

Страница 20: ...ries according to manufacturer s instructions ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig håndtering Udskiftning må kun ske med batteri af samme fabrikat og type Levér det brugte batteri tilbage til leverandøren ADVARSEL Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries acc...

Страница 21: ...tery See Figure 8 6 Gently pull back on the metal tab to release the battery 7 Remove the battery from its socket 8 Dispose of the battery according to local ordinance 9 Remove the new lithium battery from its package and being careful to observe the correct polarity insert it in the battery socket 10 Reconnect or replace any internal components you needed to disconnect or remove 11 Replace the se...

Страница 22: ...22 Server Utilities 22 Server Utilities ...

Страница 23: ...st On 106 key Japanese keyboards the plus key has a different scan code than the plus key on the other keyboard but it has the same effect Enter Execute Command The Enter key is used to activate submenus when the selected feature is a submenu or to display a pick list if a selected feature has a value field or to select a sub field for multi valued features like time and date If a pick list is dis...

Страница 24: ...on covering pins 2 and 3 4 Reconnect the AC power power up the system 5 When the system begins beeping power it down and disconnect the AC power 6 Return the CMOS Clear jumper to the original location covering pins 1 and 2 7 Close the server chassis reconnect the AC power and power up the system Clearing the Password If the user or administrator password s is lost or forgotten moving the password ...

Страница 25: ...left side Green Blinking Activity No action required Memory fault 1 6 Identify failing memory module DIMM end front of board Amber On Fault POST code 1 4 LSB bit1 bit2 MSB Display boot 80 POST code Left rear of board Each LED can be Off Green Amber Red See the POST code table Fan Pack Fault Warn on fan failure Front center board Amber On Fault CPU 1 2 Fan Fault Identify fan failure Front center bo...

Страница 26: ...rong CMOS values are not the same as the last boot These values have either been corrupted or the battery has failed CMOS Date Time Not Set The time and or date values stored in CMOS are invalid Run Setup to set correct values DMA Error Error during read write test of DMA controller FDC Failure Error occurred trying to access diskette drive controller HDC Failure Error occurred trying to access ha...

Страница 27: ...table below lists the POST error beep codes Prior to system video initialization the BIOS uses these beep codes to inform users of error conditions The beep code occurs only when a critical error occurs or when the BIOS fails to boot to the operating system Please note that not all error conditions are supported by BIOS beep codes Table 8 Beep Codes Number of Beeps Description 1 Refresh failure 2 ...

Страница 28: ...t beeps Insert the BIOS recovery diskette An error or warning condition at boot can result in a series of beeps being issued known as beep codes These beeps have a code that identifies system or PCI card events For example some Intel RAID cards have beep codes Before checking for a system beep code error make sure the PCI card is not causing the beeping ...

Страница 29: ...rified to comply with the following electromagnetical compatibility EMC regulations when installed in a compatible Maxdata host system FCC Class A Verification Radiated Conducted Emissions USA ICES 003 Class A Radiated Conducted Emissions Canada CISPR 22 3rd Edition Class A Radiated Conducted Emissions International EN55022 Class A Radiated Conducted Emissions European Union EN55024 Immunity Europ...

Страница 30: ... than the one to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment The customer is responsible for ensuring compliance of the modified product Only peripherals computer input output devices terminals printers etc ...

Страница 31: ...upply make sure that the calculated total current loads of all the modules within the computer is less than the output current rating of each of the power supplies output circuits Place Battery Marking There is insufficient space on this server board to provide instructions for replacing and disposing of the battery For system safety certification the following statement or equivalent statement ma...