Hardware Installations and Upgrades
Installing an I/O Expansion Module
1. Squeeze the sides of the filler panel to disengage it from the server system back panel and
remove it (A).
2. Position the module over the server board, fit the front of the module into the back panel slot
(B).
3. Attach the module to the server board connector (C).
4. Secure the module with three screws (D).
Figure 28. Installing an I/O expansion module
Installing a Solid State Drive
Two SSDs or one SSD and one ODD can be installed in the server system.
1. Remove the air duct from the server system.
2. Place the solid state drive on air duct (A).
3. Secure the solid state drive with four screws (B).
4. Place the air duct back into the server system.
5. Connect the cables (C).
Figure 29. Installing a solid state drive
CAUTION
On the air duct, only the installation of SDDs is supported.