background image

11

MAXDATA Server PLATINUM 2200 IR M8

2  Server System Features

This chapter briefly describes the main features of the MAXDATA PLATINUM server system. It provides 
a list of the server system features and diagrams showing the location of important components and 
connections on the server system.

Table 3 summarizes the major features of the server system.

Table 3.  Server system features

Feature

Description

Dimensions

 

87.3 mm high

 

430 mm wide

 

704.8 mm deep

 

29 kg max chassis weight

Server board

Intel

®

 S2600GZ/S2600GL

Processor

One or two Intel

®

 Xeon

®

 E5-2600 processors with a thermal design power (TDP) 

of up to 130 W

System memory

•  S2600GL: 16 DIMM slots, 8 per processor, distributed over 4 memory channels
•  S2600GZ: 24 DIMM slots, 12 per processor, distributed over 4 memory channels
•  Up to 768 GB system memory using 32-GB LRDIMMs
•  800/1066/1333/1600 MT/s ECC Unbuffered (UDIMM), Registered (RDIMM) or 

Load-Reduced (LRDIMM) DDR3 memory

•  No mixing of UDIMMs, RDIMMs and LRDIMMs
•  DDR3 standard I/O voltage of 1.5 V and DDR3 Low Voltage of 1.35 V

Chipset

•  Intel

®

 C600 Platform Controller Hub (PCH) with integrated storage controller 

unit (SCU)

•  RAID upgrade keys supported for the SCU ports

Peripheral 
interfaces

External connections:

•  One DB-15 video connector (1 × on back panel + 1 × on front panel with 

configurations up to 8 × 3.5" or 16 × 2.5" HDD)

•  One RJ-45 serial port A connector
•  Four RJ-45 network ports for 10/100/1000 Mbit/s
•  Three USB 2.0 ports on back panel
•  Two USB 2.0 ports on front panel with configurations up to 8 × 3.5" or

 

16 × 2.5" HDD

Internal connections:

•  One USB connector for two USB 2.0 ports
•  One low-profile eUSB connector (2 × 5) for low-profile eUSB SSD
•  One DH-10 connector for serial port B
•  Two SATA III ports (6 Gbit/s)
•  Two quad mini-SAS ports (3 Gbit/s SATA/SAS) (feature activation with RAID 

upgrade keys; four SATA ports enabled by default)

Graphics

•  On-board Matrox G200 2D video controller
•  16 MB graphics memory

LAN

Intel

®

 I350 controller with four ports for 10/100/1000 Mbit/s Ethernet LAN

Expansion 
capabilities

•  Riser 1:
  - 2 × PCIe Gen III x8 with x16 connector from CPU 1
  - 1 × PCIe Gen III x8 from CPU 2
•  Riser 2:
  - 2 × PCIe Gen III x8 with x16 connector from CPU 2
  - 1 × PCIe Gen III x8 from CPU 2
•  One port for optional hardware RAID expansion (SAS ROC)
•  One port for optional I/O expansion (4 × 1-Gbit/s NIC or 2 × 10-Gbit/s NIC or FDR 

Infiniband)

•  Remote Management Module 4 network and feature key ports

Содержание PLATINUM 2200 IR

Страница 1: ...User s Manual MAXDATA Server PLATINUM 2200 IR...

Страница 2: ...2...

Страница 3: ...d Upgrades 25 Before You Begin 25 Tools and Supplies Needed 25 System References 25 Removing and Installing the Chassis Cover 25 Removing and Installing the Front Bezel 26 Removing the Front Bezel 26...

Страница 4: ...covering BIOS Defaults 43 6 Technical Reference 45 Power Supply Specifications 45 750 W Power Supply Input Voltages 45 Efficiency 45 750 W Single Power Supply Output Voltages 45 System Environmental S...

Страница 5: ...ention device from a hot swap drive carrier 27 23 Attaching a hot swap hard disk drive to a drive carrier 28 24 Removing the air duct 29 25 Removing the PCI riser assembly 30 26 Installing the PCI ris...

Страница 6: ...6...

Страница 7: ...e not trip hazards When you save data to your server s hard disks or to a floppy disk they are stored as magnetic information on the media Make sure that they are not damaged by magnetic or electromag...

Страница 8: ...2 K I O module optional E NIC 3 L Add in adapter slots via riser cards 1 and 2 F NIC 4 M Serial port B DB 9 optional G Video port Table 1 NIC LEDs LED LED state Description Left LED Off No network co...

Страница 9: ...vailable on the control panel Figure 2 Control panel A ID button with ID LED B NMI button recessed tool required for use C NIC 1 activity LED D NIC 3 activity LED E Reset button F Status LED G Power b...

Страница 10: ...PU 1 missing or failure voltage fault no memory present BMC video memory failure OFF AC power off powered down DC off state or S5 and no degraded non critical critical conditions exist HDD activity Gr...

Страница 11: ...ntegrated storage controller unit SCU RAID upgrade keys supported for the SCU ports Peripheral interfaces External connections One DB 15 video connector 1 on back panel 1 on front panel with configura...

Страница 12: ...th 750 W each Fans Five hot swap fans 60 mm 38 mm with n 1 redundancy One 40 mm fan for each power supply Server management Integrated IPMI 2 0 compatible baseboard management controller Support for R...

Страница 13: ...wer connector AR BMC firmware force update jumper block P Main power slot 2 AS 2 pin hard drive activity LED header Q CPU 2 fan connector AT 4 pin IPMB connector R CPU power in and out connectors fact...

Страница 14: ...s Figure 4 Configuration jumpers J6C4 J3A2 DCD DSR default J6C5 J6C6 J6D1 J2D1 BIOS Recovery Default Default Default Default Default Recover Clear Enabled Enabled ME force update BMC force update Pass...

Страница 15: ...ept for the ID LED the status LED and the 5V standby LED the LEDs turn on amber only if a failure occurs Figure 5 Light guided diagnostic LEDs A System ID I System fan 3 fault B System status J Memory...

Страница 16: ...Controller Configuration The AHCI Capable SATA Controller allows the following settings Enhanced supports up to two SATA devices in native IDE mode Compatibility supports up to two SATA ports in legac...

Страница 17: ...ovides eight memory channels each with two S2600GL or three S2600GZ slots CPU socket 1 CPU socket 2 Channel A Channel B Channel C Channel D Channel E Channel F Channel G Channel H A1 A2 B1 B2 C1 C2 D1...

Страница 18: ...ut S2600GZ The channels E to H which are asigned to CPU 2 can only be used when processor 2 has been configured If two processors are configured both processors can access the entire memory via Intel...

Страница 19: ...CC UDIMM support Ranks and data width Capacity per DIMM Speed at 1 or 2 DIMMs per channel SR x8 or DR x8 1 2 4 8 GB 1066 1333 MT s Supported maximum memory configuration 128 GB 16 8 GB Table 5 RDIMM s...

Страница 20: ...and 3 is mirrored The usable amount of memory is half of the installed memory Channels 0 and 2 as well as 1 and 3 must be populated with DIMMs of identical size and organization In Lockstep Channel mo...

Страница 21: ...nt components and connections on the server chassis Component Identification Internal Components Figure 11 Internal component locations A Hot swap hard drive bays B Optical drive bay C Front control p...

Страница 22: ...ive bay and front panel options Figure 12 3 5 hard drives 8 drive bays Figure 13 3 5 hard drives 12 drive bays Figure 14 2 5 hard drives 8 drive bays Figure 15 2 5 hard drives 16 drive bays Figure 16...

Страница 23: ...us LED amber Off Drive bay not in use or no error On Hard drive fault Blinking 1 Hz RAID rebuild in progress Blinking 2 Hz Drive identification on B Activity LED green On SAS HDD powered on no activit...

Страница 24: ...24...

Страница 25: ...00 IR server chassis must be operated with the top cover in place to ensure proper cooling You will need to remove the top cover to add or replace components inside the chassis Before removing the top...

Страница 26: ...Bezel 1 Unlock the bezel if it is locked 2 Remove the left end of front bezel from the rack handle A 3 Rotate the front bezel anticlockwise to release the latches on the right end from the rack handle...

Страница 27: ...rrier Two screws are at each side of the retention device or the hard drive Store the plastic retention device for future use Figure 22 Removing the retention device from a hot swap drive carrier 5 Re...

Страница 28: ...e the carrier from the chassis 4 Remove the four screws that attach the hard drive to the drive carrier Lift the drive from the carrier Store the drive in an anti static bag 5 If you are not installin...

Страница 29: ...Carefully push in the two latches on the air duct A 2 Rotate the back edge of the air duct up to disengage the two tabs from the fan bulkhead B 3 Pull the air duct to the back and upwards away from th...

Страница 30: ...nd unplug all peripheral devices and the AC power cable 3 Remove the chassis cover 4 Install any necessary add in cards into the PCI riser assembly 5 Install any cables onto add in cards that require...

Страница 31: ...Remove the filler panel from the add in card slot and remove the screw A 6 Insert the add in card until it seats in the riser connector B 7 Secure the add in card with the screw you removed in step 5...

Страница 32: ...or C 4 Secure the module with three screws D Figure 28 Installing an I O expansion module Installing a Solid State Drive Two SSDs or one SSD and one ODD can be installed in the server system 1 Remove...

Страница 33: ...t have a redundant power supply installed you must power down your server system before replacing the power supply Removing a Hot swap Power Supply To replace the power supply use the following instru...

Страница 34: ...with S2600GZ 24 DIMM mainboard Memory slot 3 needs to be populated on all memory channels 24 2 5 or 12 3 5 hard drive bay configuration Memory slot 2 and slot 3 on S2600GZ need to be populated on all...

Страница 35: ...n off the server 3 Disconnect the AC power cord s from the server 4 Remove the chassis cover 5 Remove the memory and processor air duct 6 Locate the processor sockets see Figure 3 on page 12 7 Disconn...

Страница 36: ...ter use Figure 35 Removing the protective cover from the load plate 12 Carefully lower the load plate over the processor to close it Figure 36 Closing the load plate 13 Latch the locking levers in rev...

Страница 37: ...r 8 Lift the heat sink from the processor If it does not pull up easily twist the heat sink again Do not force the heat sink from the processor Doing so could damage the processor 9 Open the load plat...

Страница 38: ...EMENT Danger d explosion en cas de remplacement incorrect de la pile Remplacez la uniquement par une pile du m me type ou d un type quivalent recommand par le fabricant Mettez au rebut les piles usag...

Страница 39: ...cover and locate the battery 5 Gently push the metal tab to unlock the battery 6 Remove the battery from its socket Figure 38 Replacing the backup battery 7 Dispose of the battery according to local...

Страница 40: ...40...

Страница 41: ...een corrupted you will see other prompts but not the F2 prompt Warning CMOS checksum invalid Warning CMOS time and date not set In this condition the BIOS will load default values for CMOS and attempt...

Страница 42: ...n the selected feature is a submenu or to display a pick list if a selected feature has a value field or to select a sub field for multi valued features like time and date If a pick list is displayed...

Страница 43: ...he server and wait 10 seconds 6 Power down the server 7 Open the server chassis and move the jumper back to the default position covering pins 1 and 2 8 Close the server chassis 9 Power up the server...

Страница 44: ...44...

Страница 45: ...e DC converters on the mainboard Table 9 750 W power supply system output capability Voltage Maximum Current 12 V 62 A 12 V standby 2 1 A CAUTION The expansion slots on the server board are rated for...

Страница 46: ...46...

Страница 47: ...Directive 89 336 EEC European Union Product Regulatory Compliance Markings This product is marked with the following Product Certification Markings Table 11 Product certification markings CE Mark Pro...

Страница 48: ...ms attached to the server before opening it The power supply cord s is are the main disconnect device to AC power The socket outlet s must be near the equipment and readily accessible for disconnectio...

Отзывы: