10
Setting up the system
11
MAXDATA PLATINUM 9000-2R Server
Checking Power Cords
WARNING
The Power button on the front control panel of the server does not completely remove AC power.
To completely remove AC power from the server, you must unplug both AC power cords from the
system or from the wall outlet. Unplugging the cords removes the +12 Volt standby power that is
present when the server is powered down.
WARNING
Do not attempt to modify or use an AC power cord that is not the exact type required. You must use
a power cord that meets the following criteria:
1. Rating: For U.S./Canada cords must be UL Listed/CSA Certified, 16/3, 75C type, VW-1,
SJT/SVT, with NEMA 5-15P or NEMA 6-15P attachment plug and IEC 320 C13 input power
connector rated 15 amps. For outside U.S./Canada cords must be flexible harmonized
(<HAR>) rated 250V, 1.0 mm minimum conductor size with IEC 320 C13 input power
connector and rated for no less than 10 amps.
2. AC Attachment Connector, wall outlet end for outside U.S./Canada: The AC wall
attachment plug should be a three conductor grounding type, rated at 125 V, 15 amps and
must be for the configuration of the specific region or country. The AC wall attachment
plug must bear at least an accepted safety agency certification mark for the specific
region or country.
3. Input Power Connector, server end: The connectors that plug into the AC receptacles
on the server must be an IEC 320, sheet C13, type female connector and are rated for
125V/250V, 15 A.
NOTES
Surge Suppressor Recommendations: In geographic regions that are susceptible to electrical storms,
we highly recommend that you plug the server into a surge suppressor.
EMI Information: For information about complying with electromagnetic interference regulations,
see “Electromagnetic Compatibility” in the MAXDATA PLATINUM 9000-2R Server System Product-
Guide.