Sensor setup
The DFP or DFP-2 position sensor should be at the center of
rotation when the dancer is halfway through its travel. This is an
approximate adjustment and is intended to center the sensor
position to allow maximum rotation in both directions during
operation.
DFP
Install the DFP sensor so that its keyway is pointing towards the
top cover when the dancer is half way through its travel. This is an
approximate adjustment, and is intended to center the sensor
position to allow maximum rotation in both directions during
operation.
DFP-2
To find the electrical center point of pot rotation, use a digital
multi-meter type ohm meter to measure from the white wire
(wiper), to the red or black wire. Turn the potentiometer shaft
until the meter reads 500Ω. Install the DFP-2 sensor so that at the
500Ω meter reading, the dancer is halfway through its travel.