SAFETY INSTRUCTIONS

2 - 3

DSE-22

www.maxcess.eu

MI 1081 1 A

Personnel requirements

The tasks listed in these operating instructions may only be 

carried out by appropriately qualified personnel commissioned 

by the operator. The responsibilities of the personnel for the 

work on the system must be clearly defined by the operator.

Transport, assembly, maintenance, troubleshooting, 

disassembly:

– Specialized staff



Mechatronics engineer, industrial mechanic, etc.

Electrical connection or disconnection:

– Specialized staff



Only by a qualified electrician

Control during operation:

– Specialized staff



Machine and system operators, etc.

– Personnel or trainees trained and supervised by the system 

operator

Repair:

– Specialized staff



Service technician of Fife-Tidland GmbH

Qualified electrician

A qualified electrician is a person whose specialist training, 

knowledge and experience, as well as knowledge of the relevant 

standards, enable him to assess and perform the work assigned 

to him and to recognize and avoid possible hazards.

The electrician is specially trained for the field in which he or 

she works and is familiar with the relevant standards and 

regulations.

Содержание FIFE DSE-22

Страница 1: ...FIFE GUIDING SOLUTIONS FIFE DSE 22 Operating Instructions Infrared Light Sensor MI 1081 1 A EN...

Страница 2: ...electrician 2 3 Preventing hazards 2 4 Residual risks 2 4 INSTALLATION 3 1 Transport and storage 3 1 Mounting 3 1 Mounting location 3 1 Dimensions 3 2 Mechanical fastening 3 3 Electrical connection 3...

Страница 3: ...l as the operator who uses the sensor in production line Read operating instructions The Operating Instructions must be read and used by all persons who have the responsibility of installing commissio...

Страница 4: ...signal would automatically be switched over in that case Power supply voltage 12V The sensor provides an output signal in the range from 0 to 10mA Thus the sensor can be connected to all Fife web guid...

Страница 5: ...acquisition to Fife D MAXE controller extends the range of applications for the sensor inside the digital network environment Additional sensor data can be provided to other hardware equipment if the...

Страница 6: ...national state and local requirements for accident prevention and environmental protection Information about safety instructions The safety instructions and symbols described in this section are used...

Страница 7: ...l result in damage to the device or system Qualified electrician The electrical components may only be connected and disconnected by a qualified electrician Read operating instructions Follow these op...

Страница 8: ...or disconnection Specialized staff Only by a qualified electrician Control during operation Specialized staff Machine and system operators etc Personnel or trainees trained and supervised by the syste...

Страница 9: ...t handle or step There is a danger that the sensor will become damaged breaking off snapping resulting in personal injury Residual risks Installing the product in a machine system makes it possible to...

Страница 10: ...ed in operation All assembly tasks on the sensor must only be performed when there is no electrical power in the system Assembly tasks and mechanical settings must only be performed when the machine h...

Страница 11: ...16 20 UNFx9 M8x8 M5x5 2x 105 51 7 25 4 12 7 1 M8 threading for sensor bracket type M and MO 2 7 16 20 UNF threading for sensor bracket type type M and MO 3 Threading for air connection 4 M5 threading...

Страница 12: ...the M5 fastening screws to a max torque of 3Nm Tighten the M8 fastening screws to a max torque of 9Nm Tighten the 7 16 20 UNF fastening screws to a max torque of 12Nm 48 38 12 7 M5x5 2x 101 26 26 50 4...

Страница 13: ...upon request Type A VK D M 20 8 86 20 8 M 20 7 16 86 20 12 M 25 8 88 25 8 M 25 7 16 88 25 12 Type A VK D MO 20 8 69 20 8 MO 20 7 16 69 20 12 MO 25 8 71 25 8 MO 25 7 16 71 25 12 Sensor bracket Square...

Страница 14: ...stroy the sensor Electrical lines must not be subjected to any mechanical loads The sensor must be connected to the web guide controller according to the system diagram in the system documentation onl...

Страница 15: ...The sensor could become unusable during the operation by damages The sensor must not be placed in operation unless it has been securely mounted Depending on the material of the guided web if the web r...

Страница 16: ...for working with transparent material the sensor must always be calibrated to the contrast with the web guide controller LEDs in normal operation Field of view completely uncovered The outer LED flic...

Страница 17: ...ent and a soft cloth When selecting synthetic cleaning agents note chemical resistance page 7 1 No additional maintenance tasks are required for the sensor Decommissioning 1 Turn off the electrical po...

Страница 18: ...s still possible to use the sensor Error n 4 7 Only the blinking pattern of an error is displayed The sensor is no longer supplying a valid output signal Fault In the event of an error the LEDs flash...

Страница 19: ...optional Ambient conditions Ambient temperature 5 C 60 C Relative humidity up to 85 non condensing Operating altitude max 5000m above sea level Materials used Housing Aluminum casting alloy EN AC 4600...

Страница 20: ...nal 0 10mA to 400 at 12V 10 15V Power supply 4 20mA to 200 at 24V 20 28V Power supply Digital data exchange via RS 485 when connected to selected FIFE web guide controllers e g D MAXE Pin assignment S...

Страница 21: ...ompanying the product in a safe place This will allow us to help you more quickly in the event that service is required Adresses To request service or if you need replacement parts please contact one...

Страница 22: ...cess eu NORTH CENTRAL AND SOUTH AMERICA Tel 1 405 755 1600 sales maxcessintl com www maxcessintl com CHINA Tel 86 756 881 9398 info maxcessintl com cn www maxcessintl com cn JAPAN Tel 81 43 421 1622 j...

Отзывы: