GENERALITY
When
installing
or
servicing
the
unit,
it
is
necessary
to
strictly
follow
the
rules
listed
in
this
manual,
to
conform
to
all
the
specifications
of
the
labels
on
the
unit,
and
to
take
any
possible
precautions.
Not
observing
the
rules
reported
on
this
manual
can
create
dangerous
situations.
After
receiving
the
unit,
immediately
check
its
integrity.
The
unit
left
the
factory
in
perfect
condition;
any
eventual
damage
has
to
be
questioned
to
the
carrier
and
recorded
on
the
Delivery
Note
before
signing
it.
ADVANTIX
SPA
has
to
be
informed,
within
8
days,
of
the
extent
of
the
damage.
The
Customer
should
prepare
a
written
statement
of
any
severe
damage.
WARNING:
The
N
‐
i
‐
HP
units
are
designed
for
outdoor
installation.
The
place
of
installation
must
be
entirely
far
away
from
fire
risk.
All
the
necessary
measures
should
be
adopted
in
order
to
prevent
the
fire
risk
in
the
place
of
installation.
The
outdoor
ambient
temperature
shall
not
exceed
46°C.
Above
this
value,
the
unit
is
no
longer
covered
by
the
directives
in
force
in
the
area
of
pressure
equipment.
WARNING:
The
unit
should
be
installed
so
that
adequate
clearance
is
available
for
maintenance
and
repairation.
The
warranty
does
not
cover
costs
related
to
platforms
or
handling
equipment
necessary
for
any
maintenance.
All
maintenance
and
testing
operations
should
be
carried
out
only
by
QUALIFIED
PERSONNEL.
Before
any
operation
on
the
unit,
make
sure
the
power
supply
is
disconnected.
WARNING:
Inside
the
unit,
there
are
some
moving
parts.
Be
especially
careful
when
working
near
them,
even
if
the
unit
is
off.
The
temperatures
of
heads
and
exhaust
piping
of
the
compressor
are
usually
high.
Therefore
be
careful
when
working
near
condensing
coils.
The
aluminum
fins
are
very
sharp
and
can
cause
serious
injuries.
After
the
maintenance
operations,
close
the
panels
tightly
with
the
fastening
screws.
7.2
LIFTING
AND
HANDLING
When
the
unloading
and
the
placement
of
the
unit,
it
is
highly
recommended
to
avoid
any
sudden
or
violent
motion
in
order
to
protect
the
inner
components
and
the
frame.
The
units
can
be
lifted
by
mean
of
a
forklift
or,
otherwise
by
mean
of
belts,
making
sure
to
damage
the
lateral
panels
and
the
cover
of
the
unit
using
a
structure
of
spacers
as
shown
in
the
drawing.
In
this
context,
it
is
necessary
to
hook
indirectly
the
unit
to
the
basement
but
on
two
steel
pipes
of
adequate
dimension
that
to
pass
into
the
appropriate
holes
situated
in
the
same
basement
of
the
unit).
It
is
important
to
keep
the
unit
horizontal
during
these
operations.
1)
Handling
with
forklift
under
the
pallet
2)
Handling
with
forklift
under
the
unit
using
the
appropriate
windows
of
passing
forks
3)
Handling
by
mean
of
belts
7.3
LOCATION
AND
MINIMUM
TECHNICAL
CLEARANCES
All
the
N
‐
i
‐
HP
models
are
designed
for
outdoor
installations;
any
cover
over
the
unit
or
locating
near
trees
(even
if
they
partially
cover
the
unit)
has
to
be
avoided
in
order
to
allow
the
air
recirculation.
It
is
advisable
to
realize
a
supporing
basement,
with
adeguate
size
similar
to
unit
foot
‐
print.
The
unit
vibration
level
is
very
low:
it
is
advisable
however,
to
fit
a
rigid
rubber
band
between
basement
and
unit
base
‐
frame.
It
is
also
possible
to
install
anti
‐
vibration
supports
(springs
or
rubbers)
to
keep
vibrations
at
a
very
low
level.
An
absolute
care
has
to
be
taken
to
ensure
adequate
air
volume
to
the
condenser.
The
re
‐
circulation
of
discharge
air
has
to
be
avoided;
failure
to
observe
this
point
will
result
in
poor
performance
or
activation
of
safety
controls.
For
these
reasons
it
is
necessary
to
observe
the
following
clearances: