6
1.2 Indoor units specifics
MODELS
BDLM26A2
BDLM36A2 BDLM53A2
Power supply
V-Ph, Hz
230V 220 ~ 240V
○
,1, 50Hz
kW 2.600
3.500
5.300
Total capacity
Btu/h 8,8
11,9
18,0
Power input
W
10
10
55
Coo
lin
g
Absorbed current
A
0,04
0,04
0,3
kW 2.800
3.800
5.800
Total capacity
Btu/h 9,5
12,9
19,7
Power input
W
10
10
55
Heating
Absorbed current
A
0,04
0,04
0,3
Air flow volume (SH/H/M/L)** (m
3
/h) 500
630
850
Dehumidifying volume
l/h
0,6
1,4
1,8
Fan motor speed (SH/M/L)
(r/min)
1320/1200/1100/950 1280/1080/1000/920 1420/1250/1150/1050
Fan Motor Capacitor
μ
F
1
1
1,5
Fan motor full load Amp (FLA)
A
0,144 0,22 0,31
Output of fan motor
W
10
20
20
Motor model
FN10A-PG
FN20J-PG
FN20V-PG
Fan type-piece
Cross flow fan – 1
Diameter-Length
mm
Ø85 X 596
Ø92 X 645
Ø98 X 710
Evaporator
Aluminum fin-copper tube
Pipe diameter
mm Ø7
Row-Fin gap
mm
2-1,5
2-1,4
2-1,4
Indoor C
oil
Coil length (l)xheight (H)xcoil width (L)
mm 581X267X25,4
690X267X25,4
715×304,8x25,4
Swing motor model
MP24AA
MP28VB
Output of swing motor
W
1,5
1,5
2,0
Fuse
A PCB
3,15A
Indoor sound level (H/M/L)
dB(A)
39/34/28
40/35/30
43/40/35
Dimension (W/D/H)
mm
790X174X265
845X180X275
940/200/298
Dimension of package (W/D/H) mm
870x248X355
918x258X370
1013X288X395
Net weight/Gross weight
kg 9/11 10/12,5 13/16
Liquid pipe
mm Ø6
Ø6
Ø6
Gas pipe (to indoor unit)
mm Ø9,52
Ø9,52
Ø12,7
The data of specifications are subject to change without prior notice. Please refer to the actual data specified on the
nameplate of the unit.
Note:
Test conditions:
Indoor side state
Outdoor side state
Standard condition
Dry bulb temp. °C
Wet bulb temp. °C
Dry bulb temp. °C Wet bulb temp. °C
Rated
cooling
27 19 35 24
Max.
cooling
32 23 48 26
Min. cooling
21
15
18
-
Rated heating
20
15
7
6
Max heating
27
-
24
18
Min. heating
20
15
-15
-16
3) Microphone at a distance of 1m from the unit.
Approximate calculation from Sound Pressure Level to Sound Power Level:
- Average Sound Pressure Level
p
L
=10*lg
[
]
2
1
*
1
.
0
*
1
.
0
10
10
(
*
2
/
1
P
P
L
L
+
.
1
P
L
: Sound pressure level of front test point.
2
P
L
: Sound pressure level of side test point for indoor unit
2
1
,
P
P
L
L
.
- Approximate Sound Power Lever
p
W
L
L
=
+10.