15
b) Timer off: At unit on, can set up the Timer Off function, when Timer Off act, the unit will turn off, the Timer interval is
0.5hr, setting range is 0.5-24hrs.
Hours setting for Timer:
a) Timer on: If unit is running then to set up the Timer On, the unit will go on running, if the unit is off to set up the Timer
On, when Timer On acts, the unit will run at the presetting modes.
b) Timer off: If unit is off then to set up the Timer Off, when setting the Timer off, the unit stand by, if unit is turned on to
set up Timer Off, when the Timer Off act, the system will stop to work.
c) Timer change: When unit is running in Timer mode, by operate the On/Off of remote controller to turn on or turn off the
unit, can reset up the Timer function, the unit will
run at the mode of last setting.
If unit is running, at the same time to set up Timer On and Timer Off, the system will keep the present setting status, after
the Timer On. When system is running, at the same time to set up Timer On and Timer Off, the unit will keep the current
presetting working status, if Timer Off act, the unit will stop working.
When unit is stop running, at the same time to set up the Timer On and Timer Off, the unit will keep stop running, until
Timer On act, the unit will start to work, after this when Timer On of every day act, it will run at presetting modes, when
Timer Off act, the unit will stop to work.
If the setting for the Timer Off and Timer On are the same, the Timer Off will act.
6.3.5 Memory function
Contents of memory: Modes, Up and Down Swing, Light, Setting Temp. Setting fan speed, Common setting for Timer
(Hours will not memorized). After Timer Off, when re-power on, the unit will automatically turn on and run at memorized
contents.
There is no Timer Setting in the remote control order that the unit will memorize the remote control order of last setting
and it will run at that mode.
6.3.5 I Feel function
When controller received the orders that the controller will work according to ambient temperature which is sent by remote
control (Except Defrost and Anti-cool wind, it will still adopt the air conditioner self ambient sensor sampling value), the
remote control in every 10mins, to send the ambient temperature value to controller. 11mins later, the controller haven’t
received the ambient temperature value from the remote control that the air conditioner will run itself ambient temperature.
If there is no setting function that the ambient temperature will adopt the AC sensor sampling value. Power off will not
memorize this function.
6.3.7 TURBO function
Only in Cool or Heat mode, the Turbo setting is available, when controller received this order, the indoor fan will run at
super high, sent the outdoor unit Turbo signal and sent the high fan speed.
6.4. Displayer
6.4.1 Basic display
(1) After powered on, the displaying failure will fully displayed then only power indicator light on.
(2) Remote control to turn on the unit, the running indicator and cooling indicator will light on. Heat mode: the running
indicator and heating indicator will light on. In dehumidifying mode, running indicator and dehumidifying indicator light on.
Fan mode, running indicator light on. Auto mode: running indicator and actual running mode indicator will light on.
(3) If turns off the Light button, that all display will be turned off (still valid at unit off).
(4) After set up the SLEEP function, the displayer will keep original displaying status that is Sleep function will not affect
the light on and off.
6.4.2 Forcible Defrosting Function
When the unit is in Heat mode and set temperature is 16°C, press “+, -, +, -, +, -,” successively for 5s, and the indoor unit
will enter forcible defrosting setting and send the signal to the outdoor unit.
When the indoor unit receives forcible defrosting signal from the outdoor unit, it will exit forcible defrosting setting.