G-Series User Manual Rev2020A
33
1
Rev 2018A
an ISO 9001:2015 certified company
Max Machinery, Inc.
33A Healdsburg Avenue
Healdsburg, CA 95448
maxmachinery.com
T
+ 1 707.433.2662
©2008-2020
Positive Displacement Flow Meters
Gear Type, G-Series
* See temp chart in product manual.
** Receiver portion of 2 part transmitters are not rated Ex-Proof, consult factory.
*** Tefl on® not used above 90°C for this high pressure rated product.
† Not available for hazardous location use. (Exceeds 130
°
C temp. limit.)
Product includes single directional calibration, bi-directional
calibrations for analog and quadrature devices are optional.
Model G015
Flow Meter Selections
Transmitter Selections
Model #
HS
/
/
1
-
Non-Standard Options
Bi-Directional Cal: BID
1
Transmitter Type
Max Flow Range
Output Type
4 Liters/Min
G004
A
A
4-20mA Output - Powered by 24 Vdc
15 Liters/Min
G015
A
B
4-20mA Output - Powered by 12 Vdc
45 Liters/Min
G045
A
C
0-10 Volt Output - Powered by 24 Vdc
105 Liters/Min
G105
A
D
0-10 Volt Output - Powered by 12 Vdc
240 Liters/Min
G240
P
N
5V Pulse/Freq. - Powered by 5-26 Vdc
Q
N
5V Quadrature - Powered by 5-26 Vdc
P
S
Current Sinking, Single Phase
Pressure
Temperature Rating
6000 psi (414 bar)
HS
1
90°C Industrial / 75°C Haz-Loc
Note: G240 limited to 4000 psi (240 bar)
2
155°C Ind. / 130°C Haz-Loc, 2 Part **
if specifi ed with NPT connections
3 225°C Industrial, 2 Part †
Fluid Connection
Electrical Connection
NPT
1
1
Industrial, Turck® Connector
SAE
2
2
Hazardous Location, 1/2 Inch Conduit*
Seal Selection
Signal Type
Viton® - FKM
1
P Pulse
Tefl on® - PTFE*** 3
A
Analog
Perfl uoroelastomer - FFKM
5
Q Quadrature
Options
None NA
Heat Trace Option HT
Содержание G Series
Страница 24: ...G Series User Manual Rev2020A 21 Dimensions G004 SPECIFICATIONS ...
Страница 26: ...G Series User Manual Rev2020A 23 Dimensions G015 SPECIFICATIONS ...
Страница 28: ...G Series User Manual Rev2020A 25 Dimensions G045 SPECIFICATIONS ...
Страница 30: ...G Series User Manual Rev2020A 27 Dimensions G105 SPECIFICATIONS ...
Страница 31: ...G Series User Manual Rev2020A 28 Dimensions G240 SPECIFICATIONS MODEL G240 WITH INDUSTRIAL HOUSING ...
Страница 35: ...G Series User Manual Rev2020A 32 Charts G105 Pressure Drop Graph G240 Pressure Drop Graph ...