![Max Machinery G Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/max-machinery/g-series/g-series_user-manual_1742944012.webp)
G-Series User Manual Rev2020A
9
LED Rotation/Output Indicators
All Max transmitters incorporate an alternating red/green or blue/green LED to indicate magnet rotation in the meter.
The color changes each 1/2 revolution of the meter. Additionally, when no flow signal is present, a rapidly flashing red
light indicates the following errors:
Frequency (PN ending N/- or S/-):
Flashes 8x per second indicate magnet is not detected
Analog (PN ending A/-, B/-, C/-, D/-):
Flashes 2x per second indicate excessive temperature
Flashes 8x per second indicate magnet is not detected
Flashes 16x per second indicate a wiring fault in the output circuit
Note: There are no selections or adjustments on the circuit board. Setting changes are made through the Interface
Software Kit (SFT-KIT-001), sold separately.
High Temperature Instructions
Troubleshooting
Orient your meter so the transmitter is to the side or below to minimize heat transfer by convection from the flow meter
to the transmitter. The transmitter is the most heat sensitive element in the system. Consult the table on
for
specific limits on fluid and ambient maximum temperatures. When operating in the upper temperature ranges, always
insulate the meter but leave the transmitter housing exposed so it radiates heat. An optional heater block can be used
on the flow meter to keep it at the fluid operating temperature. For substances solid at room temperature, a heater
block may be required to keep material molten to flow through the meter.
FLOW
INSULATION HERE
RADIATE HEAT HERE
Содержание G Series
Страница 24: ...G Series User Manual Rev2020A 21 Dimensions G004 SPECIFICATIONS ...
Страница 26: ...G Series User Manual Rev2020A 23 Dimensions G015 SPECIFICATIONS ...
Страница 28: ...G Series User Manual Rev2020A 25 Dimensions G045 SPECIFICATIONS ...
Страница 30: ...G Series User Manual Rev2020A 27 Dimensions G105 SPECIFICATIONS ...
Страница 31: ...G Series User Manual Rev2020A 28 Dimensions G240 SPECIFICATIONS MODEL G240 WITH INDUSTRIAL HOUSING ...
Страница 35: ...G Series User Manual Rev2020A 32 Charts G105 Pressure Drop Graph G240 Pressure Drop Graph ...