Table 7-1.
FL
error
code /
display
Symptom
Probable cause
Signal to check
Normal voltage and
waveform / values
Signal
name
Location
PLAY
STOP
E00
Normal
-----
-----
-----
-----
-----
E01
Focus and
tracking
offset
adjustments
has not been
completed in
the specified
time period.
1. IC702’s clock input X1 IN, IC702’s power
supply (V
DD
) or its reset (/RST) is invalid.
2. Any signal MDATA, MCLK, MLD or SENSE
to/from IC601 are invalid.
MDATA IC702-pin 8
0 V
MCLK IC702-pin 7
3.3 V
MLD
IC702-pin 9
3.3 V
/RST
IC702-pin
18
3.3 V
3.3 V
X1 IN
IC702-pin
58
X2 OUT IC702-pin
59
E02,
E03,
E05,
E06,
E07,
E09,
E0A,
E0B,
E0D,
E0E,
E0F
The test disc
does not play
consistently.
1. The disc is scratched or dirty.
2. Focus or tracking servo is malfunctioning
(Check waveforms voltages and circuit
constants).
3. Spindle driver is malfunctioning.
4. Optical pickup is malfunctioning.
FE
IC702-pin
32
1.6 V
TE
IC702-pin
33
1.6 V
FOD
IC702-pin
28
1.6 V
1.6 V
TRD
IC702-pin
27
1.6 V
1.6 V
/RFDET IC702-pin
38
0 V
3.3 V
RF
TJ701
0.9 V
STAT
IC702-pin
17
3.2 V
0 V
FL
error
code /
display
Symptom
Probable cause
Signal to check
Normal voltage and
waveform / values
Signal
name
Location
PLAY
STOP
20
Содержание SL-PG4
Страница 5: ...4 Caution for AC Mains Lead 5 ...
Страница 8: ... Follow the Step 1 Step 3 of item 6 1 8 ...
Страница 11: ...11 ...
Страница 12: ...12 ...
Страница 13: ...13 ...
Страница 14: ...14 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 27: ...27 ...
Страница 28: ...15 Terminal Function of ICs 15 1 IC601 C2BBFE000100 System Control FL Drive 28 ...
Страница 41: ...R14 ERDS2FJ103 1 4W 10K 1 41 ...
Страница 44: ...18 Loading Unit Parts Location 44 ...
Страница 45: ...19 Packaging 45 ...
Страница 46: ...F010400000YM MT KH 46 ...