Chapter 7 Respective Parameter Setup
-
34 -
[WO-4841;JL4-V
・
VC-3
~
6-34]
No. Code Setting
item
Function
Setting
range
Initial
value
14 2rL
No.
2
Request signal
input select
This should be set for the type of No. 2
request signal.
Hereinafter same as above.
Same as
above
Same
as
above
15 3rL No.3
Request
signal input
select
This should be set for the type of No. 3
request signal.
Hereinafter same as above.
Same as
above
Same
as
above
16 4rL No.4
Request
signal input
select
This should be set for the type of No. 4
request signal.
Hereinafter same as above.
Same as
above
Same
as
above
17 5rL No.5
Request
signal input
select
This should be set for the type of No. 5
request signal.
Hereinafter same as above.
Same as
above
Same
as
above
18 6rL No.6
Request
signal input
select
This should be set for the type of No. 6
request signal.
Hereinafter same as above.
Same as
above
Same
as
above
19 bt1
No.
1
Batch gate timer
No.1 Batch gate timer should be set for
opening time of automatic slide gate when the
batch conveyance option is performed.
This should be set so that any desired amount
is conveyed.
0.0 - 99.9
sec
1.0
20
bt2
No.2 Batch gate
timer
No.2 Batch gate timer should be set for
opening time of automatic slide gate when the
batch conveyance option is performed.
Hereinafter same as above.
Same as
above
Same
as
above
21
bt3
No.3 Batch gate
timer
No.3 Batch gate timer should be set for
opening time of automatic slide gate when the
batch conveyance option is performed.
Hereinafter same as above.
Same as
above
Same
as
above
22
bt4
No.4 Batch gate
timer
No.4 Batch gate timer should be set for
opening time of automatic slide gate when the
batch conveyance option is performed.
Hereinafter same as above.
Same as
above
Same
as
above
23
bt5
No.5 Batch gate
timer
No.5 Batch gate timer should be set for
opening time of automatic slide gate when the
batch conveyance option is performed.
Hereinafter same as above.
Same as
above
Same
as
above
24
bt6
No.6 Batch gate
timer
No.6 Batch gate timer should be set for
opening time of automatic slide gate when the
batch conveyance option is performed.
Hereinafter same as above.
Same as
above
Same
as
above
Содержание JL4-4V-3~6