background image

Model No: 

MW15 

Type 7 

stage 

Input 240VAC 

50Hz 

Output Voltage 

12Volt DC 

Output current 

5/10/15Amp 
Selectable / Variable 

Minimum Start Volt 

1.5Volt 

CHARGE CONTROL 

Desulphation 

High Frequency Pulse Charge  

(

DEPENDENT ON  DIAGNOSIS

Soft Start 

Yes 

Bulk Charge 

14.1V (Gel) 
14.7V (SLA) 
15.1V (Calcium) 

Absorption 

Constant voltage with automatic amperage  control 

Equalization Automatic 

Analysis 

Automatically detects faulty batteries. Led warning and 
audible alarm 

Recondition 

Constant current automatically varied  
14.5v (Gel), 15.2V (SLA), 15.6V (Calcium) 

Float 

13.7V (SLA), 13.7V (Calcium), 13.3V (Gel) 

BATTERY RANGE 

Deep Cycle 

17 

~

 300Ah 

Automotive 

150 

~

 950CCA 

 4 

 5 

CHARGING INSTRUCTIONS: 

 

• 

Check liquid level in battery.

 

 

Before attempting to charge the battery remove vent caps and check liquid level (not re-

quired for sealed lead acid and maintenance free batteries). Top up with Matson           

distilled water if need and replace vent caps 

 

• 

Charging a battery not in a vehicle:

 

 

Ensure 240Volt power supply is OFF.  

 

Connect black (negative) charging clamp to negative battery post. 

 

Connect red (positive) charging clamp to positive battery post. 

 

Turn on 240Volt power source. 

 

Set battery type. (Chemistry selection) 

 

 Select charge rate. (Amperage output) 

 

• 

Charging a battery in a vehicle: 

 

Ensure 240Volt power supply is OFF.

 

 

Position input cable and output cable away from risk ie: fans, bonnet or door 

 

Most vehicles in Australia are negative earth (black cable to chassis of vehicle) 

 

In this case connect red (positive) charge clamp to positive terminal of battery 

 

Connect black (negative) charge clamp to chassis of vehicle away from any moving   

 parts 

 

 

Turn on 240Volt power source 

 

Set battery  type. (Chemistry selection) 

 

Select charge rate. (Amperage output) 

 

• 

Disconnecting the charger: 

 

Ensure 240Volt mains supply is turned off and removed from power socket 

 

Remove black (negative) charger clamp from battery post or vehicle chassis first 

 

Remove red (positive ) charger clamp from battery post next. 

 

 

 

 
 