background image

RA3800 Operation

Initial Charge

Before using the jump start for the first time, charge the unit for 24 hours, or until the MAC02 Battery
Charger supplied with the equipment indicates fully charged.

Testing RA3800 Charge Status

Test 12VDC Status - Switch to 12V position then press and hold TEST switch. VOLT METER indicates
status

Test 24VDC Status - Switch to 24V position then press and hold TEST switch. VOLT METER indicates
status

Operation

1.

Turn the ignition off before making connections

2.

Ensure the RA3800 voltage selector is in the OFF position

3.

Attach the red / positive

+

clamp to the battery positive terminal

4.

Attach the black / negative

-

clamp to the battery negative terminal

5.

The RA3800 voltmeter displays the voltage of the battery being started. If less than 3 volts on 12 volt
setting, or 6 volts on 24 volt setting - do not attempt to jump start the vehicle. The battery voltage is
too low - an attempted jump start would be dangerous. Replace the battery.

6.

If displayed voltage is above 3 volts on 12 volt setting, or 6 volts on 24 - select either 12V or 24V

7.

Keep cables clear of moving objects

8.

Keep people clear of the battery area

9.

Turn vehicle ignition on.

If vehicle does not start after 6 seconds,

allow the RA3800 to cool for 3

minutes before attempting to restart the vehicle. This avoids damage to the unit.

10.

Once started, disconnect the black / negative

-

clamp from the battery negative terminal. Then remove

the red / positive

+

clamp.

Risk of Short Circuit.

The REVERSE polarity led and buzzer only provides an indication of a short circuit
if the RA3800 is switched OFF.

Leave the RA3800 on charge when not in use - the MAC02 is a Charger / Maintainer
and will maintain the batteries in peak condition longer.

Turn the switch to the 12V

position for charging. In the OFF position - only 1 of the 2 batteries are charged

7

RA3800 | 20150211

Содержание RA3800

Страница 1: ...RA3800 JUMP START...

Страница 2: ...Revision Status Topic Revision Change Rev Document Released 20150211 RA3800 20150211 2...

Страница 3: ...Contents Revision Status 2 Safety 4 General Information 5 RA3800 Operation 7 MAC02 Charger 8 Maintenance and Fault Finding 10 Warranty 12 3 RA3800 20150211...

Страница 4: ...e manner 10 DO NOT leave the jump start in a total discharge state for any period of time permanent battery damage can result When not in use leave the jump start connected to the supplied battery cha...

Страница 5: ...e Power Source 1 The jump start can power most equipment incorporating a 12 volt DC male adapter The jump start DC outlet has overload protection DC power is generated only through the DC outlet 2 Use...

Страница 6: ...Surge Spike protection when unit is in ON position Voltage and Current Protection Green flashing LED Antizap Operational Indication Red LED and Warning Buzzer in the OFF position only Reverse Connect...

Страница 7: ...tting do not attempt to jump start the vehicle The battery voltage is too low an attempted jump start would be dangerous Replace the battery 6 If displayed voltage is above 3 volts on 12 volt setting...

Страница 8: ...Turn the RA3800 12V OFF 24V switch to the 12V position for charging 3 Plug MAC02 charger into 240VAC and switch power on 4 Plug MAC02 male plug into the 12VDC socket on the front of the RA3800 5 MAC02...

Страница 9: ...Leave the RA3800 on charge when not in use the MAC02 is a Charger Maintainer and will maintain the batteries in peak condition longer 9 RA3800 20150211...

Страница 10: ...mp start clamp Ensure they are well crimped or 2 Ensure power switch is in the ON position Frequently Asked Questions FAQ Q How many jump starts can I expect from a fully charged unit before needing t...

Страница 11: ...e with the applicable regulations Battery Removal Procedure 1 Ensure both booster clamps are securely stored in their compartments on each side of the jump start 2 Place the jump start front side down...

Страница 12: ...respect of a breach of a consumer guarantee or any warranty made under these warranty terms and conditions for any products not of a kind ordinarily acquired for personal domestic or household use is...

Страница 13: ...are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits given to the customer in this war...

Страница 14: ...A3800 Alternative Power Supply 5 RA3800 Multiple Power Supply 5 RA3800 Battery Removal 11 RA3800 Charge Status 7 RA3800 Maintenance 10 RA3800 Operation 7 S Safety Warnings and Cautions 4 Safety and De...

Отзывы: