34 Chapter 4: Matrox Radient eV-CXP hardware reference
An auxiliary output signal can reroute a CoaXPress trigger or GPIO signal to
another device. You can also route an exposure timer signal on an auxiliary output
signal.
Note that you can designate the auxiliary input and output signals in the DCF
with Matrox Intellicam. When you route an external signal (not a CoaXPress
signal) to or from an auxiliary signal, verify that the external signal meets the
electrical specifications of the auxiliary signal.
The following table summarizes the auxiliary functionality that the Matrox
Radient eV-CXP supports using its auxiliary I/O signals. The table also
documents the MIL constants to use. Note that for trigger and user-defined
signals, the number suffix of the MIL constants depends on the numbering mode
selected (
MdigControl()
with M_HARDWARE the required
numbering mode).
There are two numbering modes:
•
Relative mode (M_RELATIVE).
In this mode, one auxiliary I/O connector (one
set of 8 auxiliary signals) is designated to each CoaXPress acquisition path. The
auxiliary signals on each connector use the same MIL constants.
•
Absolute mode (M_ABSOLUTE).
In this mode, the auxiliary signals can be
routed to any of the CoaXPress acquisition paths. The MIL constants follow the
same enumeration as their corresponding auxiliary signals.
For example, in absolute mode, AUX(TRIG)_TTL_IO_5 can be defined as an
exposure output signal, a trigger input signal (
M_HARDWARE_PORT5
), or a
user-defined input/output signal (
M_USER_BIT...
+ 5). This auxiliary signal can
be used for any acquisition path.
Содержание Matrox Radient eV-CXP