Matrox Maevex 5150 Скачать руководство пользователя страница 5

Matrox Maevex Series – User Guide

5

Matrox safety information

To ensure safe and reliable operation of your Matrox product, to avoid personal injury, and to prevent 
damage to your computer or Matrox hardware, read the following guidelines.

Installation and operation

„

Read and retain all instructions. Only use your Matrox product according to the 
instructions, operating ranges, and guidelines provided in the Matrox user guide and 
other related Matrox documentation. Failure to follow these instructions could result in 
damage to your product or injury to the user or installer.

„

Don’t expose your Matrox product to rain, water, condensation, or moisture.

„

Always turn off your computer, unplug it, then wait for it to cool before touching any of 
the internal parts of your computer or installing your Matrox product.

„

Static electricity can severely damage electronic parts. Before touching any electronic 
parts, drain static electricity from your body (for example, by touching the metal frame 
of your computer).

„

When handling a card, carefully hold it by its edges and avoid touching its circuitry.

„

Don’t stack devices or place devices so close together that they’re subject to recirculated 
or preheated air.

„

Don’t operate your system or Matrox product near a heat source or restrict airflow to 
your system, and make sure the ambient temperature doesn’t exceed the maximum 
recommended temperatures. Don’t block ventilation holes on your unit or system.

If a power supply (internal or external) was included with your 
product

„

Don’t place the external power supply directly on top of the device.

„

Only use power supplies originally supplied with the product or use a replacement that’s 
approved by Matrox. Don’t use the power supply if it appears to be defective or has a 
damaged chassis.

„

Don’t defeat the safety purpose of the polarized or grounding-type plug. A polarized 
plug has two blades with one wider than the other. A grounding-type plug has two blades 
and a third grounding prong. The wide blade or the third prong are provided for your 
safety. If the provided plug doesn’t fit into your outlet, consult an electrician to replace 
the obsolete outlet.

Содержание Maevex 5150

Страница 1: ...ENGLISH User Guide 20245 301 0110 2017 01 16 Matrox Maevex Series 6100 Encoder 5150 Encoder 5150 Decoder...

Страница 2: ...sold separately 9 Installation overview 9 Getting started 10 Understanding your Maevex environment 10 Setting up your Maevex environment 11 Installing and connecting your Maevex 6100 encoder 12 Before...

Страница 3: ...ation 31 Specifications 31 External power supply 34 Environmental 34 Supported standards 35 Appendix A Firewall requirements 36 PowerStream 36 Firmware updater 36 Maevex devices 37 Accessing your Wind...

Страница 4: ...4 Matrox Maevex Series User Guide Technical support 48 Firmware package 48 View your warranty information 48 Register your Matrox product 49...

Страница 5: ...he metal frame of your computer When handling a card carefully hold it by its edges and avoid touching its circuitry Don t stack devices or place devices so close together that they re subject to reci...

Страница 6: ...ditions and guidelines For more information see your Matrox user guide Invisible laser radiation may be emitted from disconnected fibers or connectors Don t stare into beams or view directly with opti...

Страница 7: ...at appears on screen Italics for emphasis file names paths publication titles and new terms Bold Italics for emphasis Keyboard keys in square brackets with a plus sign separating keys that you press s...

Страница 8: ...r supply Software available Matrox PowerStream Plus to use your Matrox product Matrox PowerStream Plus software supports Windows 10 64 bit Windows 8 1 Windows Server 2012 Windows Server 2012 R2 Window...

Страница 9: ...Installation overview To install your Matrox product 1 Install your Maevex 6100 encoder see Installing and connecting your Maevex 6100 encoder page 12 2 Connect your product Maevex 6100 Encoder see I...

Страница 10: ...the input of an encoder A controller system can be used as a source Maevex 6100 encoder An encoder with multiple input support that can generate multiple streams and recordings An encoder can stream...

Страница 11: ...potential problems before you add a decoder or an encoder to your Maevex environment perform a configuration reset of your device to reset the IP address and any other settings that may prevent you f...

Страница 12: ...but still plugged in some electrical current is supplied to the motherboard This current may prevent newly installed hardware from working properly Always try to insert or remove your card as straight...

Страница 13: ...n one card see Installing multiple cards page 13 Before restarting your system connect your devices see the Connection setup section for the card you want to connect After connecting restart your syst...

Страница 14: ...her end of the cable to your video device Note To connect to this connector you need a shielded HDMI cable If your video source uses a display resolution higher than 720p60 we recommend you use a cert...

Страница 15: ...50 encoder This section describes how to connect your Maevex 5150 encoder Connection overview Maevex 5150 encoder Back 5V DC power LAN1 network VGA monitor HDMI Out monitor RS232 RS232 control device...

Страница 16: ...DMI output use an HDMI adapter to connect it to your encoder If your video source has a DVI connector use the DVI to HDMI adapter included with your Maevex product to connect it to your encoder Note T...

Страница 17: ...rial cable to connect your RS232 controller to your encoder If your encoder is using the Direct serial over IP feature in PowerStream Plus use the opposite of the serial cable required by your RS232 d...

Страница 18: ...8 Matrox Maevex Series User Guide Connecting your Maevex 5150 decoder This section describes how to connect your Maevex 5150 decoder Connection overview Maevex 5150 decoder Front RS232 RS232 device US...

Страница 19: ...ower supply is connected to the device and electrical socket the power LED is active not black For more information on LEDs see Maevex 5150 encoder and 5150 decoder page 24 HDMI 9 Connect a digital mo...

Страница 20: ...onitor has a DVI connector you need an HDMI to DVI D adapter to connect your monitor to this connector Note To connect to this connector you need a shielded HDMI cable LAN1 9 9 Connect a network cable...

Страница 21: ...your encoder is using the Direct serial over IP feature in PowerStream Plus use the opposite of the serial cable required by your RS232 device This cable may be a null modem or a straight through cabl...

Страница 22: ...y chaining to work from one decoder to another a decoder must be powered If power is lost the connection to the next decoder is also lost When daisy chaining network connections the maximum number of...

Страница 23: ...blink Card is restarting Green fast blink Configuration reset in process Amber solid Card is in maintenance mode Amber slow blink Card is restarting and is in maintenance mode Amber fast blink Card is...

Страница 24: ...Click Start File Explorer Network Under Other Devices make sure all the Maevex devices connected are listed LED color 5150 encoder 5150 decoder No LED black Device isn t powered Device isn t powered G...

Страница 25: ...ure all the Maevex devices connected are listed If prompted to enable network discovery and file sharing on your network when validating network discovery enable these two features by clicking on the...

Страница 26: ...settings including the IP configuration and password Maevex 5150 encoder or 5150 decoder Press and hold the Reset button on your device with the tip of a paper clip Reboot Press and hold the button f...

Страница 27: ...R2 Make sure the SSDP Discovery service network discovery and file sharing options are enabled For more information see page 29 Make sure you re using a DHCP server To assign an initial IP address to...

Страница 28: ...s 7 Click Start All Programs or Programs Matrox PowerStream Plus Matrox PowerStream Plus Depending on your version and configuration of Windows this part may not be necessary More information For info...

Страница 29: ...lutions This section addresses specific problems to your Matrox product that could prevent you from using your system or product Problem Maevex device not discovered on the network 1Cause Your Matrox...

Страница 30: ...work may be enabled and may prevent communication with your Maevex devices 1Solution Make sure your firewall is properly configured to allow the necessary communication between your Maevex devices and...

Страница 31: ...rofile separate plane Hi444PP Streaming protocols RTP RTSP MPEG TS Command protocols UPnP HTTPS Multi encode Multi stream 2 3840 2160 60 Hz 4 3840 2160 30 Hz 8 1920 1080 60 Hz 16 1280 720 60 Hz or num...

Страница 32: ...by your monitor may be available 1920 1200 1920 1080 1680 1050 1600 1200 1600 900 1440 900 1400 1050 1360 768 1280 1024 1280 960 1280 720 1024 768 800 600 720 576 720 480 and 640 480 Supported resolut...

Страница 33: ...tput All supported resolutions have a vertical refresh rate of 60 Hz When using a display resolution equal to or higher than 1280 720p60 we recommend you use certified high speed HDMI cables 1920 1200...

Страница 34: ...sumption 15 W Temperature operational 0 to 45 C 32 to 113 F Temperature non operational storage and transportation 40 to 70 C 40 to 158 F Humidity operational indoor 20 to 80 non condensing Humidity n...

Страница 35: ...rted standards 6100 encoder 5150 encoder 5150 decoder HDMI version 1 4b compatible 9 9 9 DVI 1 0 compatible using HDMI to DVI D adapter 9 9 9 EDID Extended Display Identification Data 1 3 and VESA E E...

Страница 36: ...g the Matrox Firmware Updater Network Port Type Inbound Outbound Functionality 20 21 TCP 9 FTP Failsafe file upload Maevex 5150 decoder only 53 TCP 9 DNS DNS requests 443 Minimum requirements TCP 9 HT...

Страница 37: ...9 9 SSH Firmware update 69 UDP 9 DHCP DHCP client 123 UDP 9 9 NTP Network Time Protocol 161 UDP 9 9 SNMP Network management public community string 443 TCP 9 HTTPS PowerStream commands and Firmware U...

Страница 38: ...sary 2 Windows 10 In the left panel click Advanced Settings Windows 8 1 7 In the left panel click Windows Firewall Advanced Settings 3 Click Inbound Rules 4 In the Actions panel click New Rule Configu...

Страница 39: ...the remote IP address add the IP range you want to use for your encoders You can use a range such as 192 168 1 0 24 or a single IP address such as 192 152 168 62 Action Select Allow the connection Pro...

Страница 40: ...ng at least 0 75 inches 1 91 cm of clearance between the top of your device and anything above it More space may be required depending on your environment When your device is resting on a plain surfac...

Страница 41: ...e provided Mountingshelfonly ThemountingshelfhasexistingholesforyourMaevexdevicethat allow the shelf to be mouzwnted facing forward or backward Use a hand screwdriver to carefully tighten each screw M...

Страница 42: ...each device You need to remove the four 4 rubber pads under your encoder before you can secure your device to the shelf Maevex 5150 decoder Your decoder has two 2 mounting holes on each side To mount...

Страница 43: ...on a single shelf Mounting Maevex decoders vertically requires the height of a 3U shelf Your Maevex decoder has two 2 mounting holes on each side Use two 2 6 mm M3 flat head screws sold separately to...

Страница 44: ...r on the back of devices with VESA compliant mounting holes To mount your decoder on a VESA mount you need two 2 angled brackets kit sold separately Your Maevex decoder has two 2 mounting holes on eac...

Страница 45: ...ckets to the mount Use four 4 6 mm M3 flat head screws included in your kit to attach your brackets to your device Mounting to a 200 mm mounting space To mount your decoder to a 200 mm mounting space...

Страница 46: ...46 Matrox Maevex Series User Guide Appendix D Installing your Matrox secure cable solution 1...

Страница 47: ...Matrox Maevex Series User Guide 47 2 3...

Страница 48: ...ugh Matrox contact your Matrox representative or visit our technical support Web site at www matrox com graphics support Information we need Please give a complete description of the problem and inclu...

Страница 49: ...User Guide 49 Register your Matrox product Please register online www matrox com graphics en registration to be eligible for customer support new product announcements and information on special offer...

Страница 50: ...Responsible Party Matrox 2002 Ridge Road Champlain NY 12919 Telephone 514 822 6000 extension 2026 Attention Conformity Group Matrox Declaration The Matrox hardware products supported by this guide co...

Страница 51: ...entsprechenden System entsprechend funktionieren Italiano Informazioni per gli utenti europei Informazioni sulla conformit Nota per i prodotti hardware Matrox supportati da questa guida Questi dispos...

Страница 52: ...isation d un jeu vid o par vous m me ou votre enfant Certaines personnes sont susceptibles de faire des crises d pilepsie ou d avoir des pertes de conscience la vue de certains types de lumi res clign...

Страница 53: ...uter Inc App Store Apple iPad Mac Mac OS Belden Inc Belden Cisco Systems Inc iOS Dolby Laboratories Inc Dolby Dolby Digital Intel Corporation Intel Pentium Thunderbolt Linus Torvalds Linux Microsoft C...

Страница 54: ...onnus nationalement ou internationalement sont galement reconnus par les pr sentes Deutsch Die eingetragenen Warenzeichen sind in den USA Kanada und oder anderen L ndern registriert Alle sonstigen nat...

Страница 55: ...Inhalte korrekt und verl sslich Weiterhin bernimmt Matrox Graphics Inc keinerlei Verantwortung f r die Benutzung dieses Handbuchs die Vervielf ltigung und oder Verteilung im Ganzen oder zum Teil wede...

Страница 56: ...Matrox Graphics Inc 1055 Saint Regis Boulevard Dorval Quebec Canada H9P 2T4 514 822 6000 graphics matrox com www matrox com graphics...

Отзывы: