The time period you define should be less than the binding timer of the router.
33.
Set the following
Timers
to the desired value, where required:
•
SIP INVITE Timer (sec):
This is the time in seconds that the phone waits for a response from the
called party after ending INVITE message. This timer starts after sending INVITE message to the
called party and stops on receipt of the provisional response or the final response or when the user
disconnects the call. On expiry of the timer, the phone terminates the call process and gives an error
tone to the user. The range of the SIP INVITE TIMER is 10-180 seconds. Default: 30 seconds.
•
SIP Provisional Timer (sec)
: This is the time in seconds that the phone waits for final response after
receiving the provisional response from the called party. This timer starts on the receipt of the
provisional response from the called party and stops on receipt of the final response from the called
party or when the user disconnects the call. On expiry of the timer, the IP phone terminates the call
process and gives error tone to the user. The range of SIP Provisional Timer is 10-180 seconds.
Default: 60 seconds.
•
General Request Timer (sec):
This is the time in seconds for which the phone waits for response of a
transaction request. This timer starts on initiating a transaction. This timer stops on receipt of a
response for the request. On expiry of the timer, the phone clears the transaction. This timer is used for
Registration request, etc. The range of the General Request Timer is 10-60 seconds. Default: 20
seconds.
34.
To debug using Syslog Client supported by the phone, configure
Debug
parameters:
•
Set
Enable Debug?
to Yes. Default: No.
When the Debug flag is enabled, the phone will send the debug messages to the Syslog Server IP
address. Debug report can be viewed on the Syslog Server or any other application which can capture
the Syslog messages/debug sent by the phone.
•
Enter the IP Address of the remote Syslog Server as
Syslog Server Address
.
•
Enter the
Server Port
, i.e. the address of the Listening Port of the Syslog Server from 1024-65535.
Default: 514.
Syslog uses the UDP as transport protocol and listens on the port 514 (the default listening port).
•
Select
Debug Levels
from these options, by selecting the respective check box:
•
SIP
•
System
•
Hardware
•
Call
•
Menu
•
User Interface
The phone supports multiple debug levels. You may select any or all of these debug levels. The Syslog
Client will send only the debug messages for the selected level to the remote server on the IP network.
For example, if the debug log of 'Call's is required, you can select this option, and disable all others.
35.
Click
Submit
to save settings.
Содержание ETERNITY NE
Страница 1: ...ETERNITY NE System Manual ...
Страница 2: ......
Страница 3: ...ETERNITY NE The Next Generation IP PBX for Small Businesses System Manual ...
Страница 10: ...vi Table of Contents ...
Страница 24: ...14 Matrix ETERNITY NE System Manual ETERNITY NE3 ETERNITY NE ...
Страница 26: ...16 Matrix ETERNITY NE System Manual ...
Страница 60: ...50 Matrix ETERNITY NE System Manual ...
Страница 123: ...Matrix ETERNITY NE System Manual 113 10 In the Select Offset box select the option Set DND for remote station ...
Страница 260: ...250 Matrix ETERNITY NE System Manual ...
Страница 292: ...282 Matrix ETERNITY NE System Manual ...
Страница 298: ...288 Matrix ETERNITY NE System Manual Click the more link to expand options ...
Страница 373: ...Matrix ETERNITY NE System Manual 363 Click Hardware to expand options ...
Страница 508: ...498 Matrix ETERNITY NE System Manual Click Submit at the bottom of the page to save changes You may log out of Jeeves ...
Страница 617: ...Matrix ETERNITY NE System Manual 607 To cancel Follow me Lift the handset of your extension Dial 130 Replace handset ...
Страница 724: ...714 Matrix ETERNITY NE System Manual For SLT Users When dialed extension is busy Dial 5 on Busy Tone ...
Страница 878: ...868 Matrix ETERNITY NE System Manual Click Submit to save your settings Click Logout to exit Jeeves ...
Страница 884: ...874 Matrix ETERNITY NE System Manual ...
Страница 912: ...902 Matrix ETERNITY NE System Manual ...
Страница 995: ...Matrix ETERNITY NE System Manual 985 ...