Vision System Manual
131
Matrix
Use following command to assign SP numbers to each trunk:
3402-1-0-0
3402-1-1-1
3402-1-2-2
Use following command to define LCR type:
3401-1-0-3
Use following command to program time zone index in mixed LCR:
3432-1-0-0800-2000
3432-1-1-2000-0800
Use following command to program number index in mixed LCR:
3433-1-0-022-#*
3433-1-1-011-#*
Use following command to assign SPs for respective number wise and zone wise LCR:
3434-1-0-0-0-2-1-0
3434-1-1-1-1-0-2-1
The table will look as below:
Number Index
Time Zone Index
022
011
B
…….
B
08.00 to 20.00
0, 3, 2, 0 0, 3, 2, 0 0, 3, 2, 0 0, 3, 2, 0 0, 3, 2, 0
20.00 to 08.00
2, 0, 3, 2 2, 0, 3, 2 2, 0, 3, 2 2, 0, 3, 2 2, 0, 3, 2
00.00 to 23.59
0 to 9
0 to 9
0 to 9
0 to 9
0 to 9
00.00 to 23.59
0 to 9
0 to 9
0 to 9
0 to 9
0 to 9
Important Point:
• To know programming details, please refer “Configuration Reports”.
Relevant Topics:
1. Trunk Access Groups 189
2. Trunk Parameters 199
3. Real Time Clock 147
=X=X=