20
7.2 SERVICE MODE - SETUP TAB - CONTINUED
CHAPTER 7: SERVICE MODE
1) Enter into Service Mode (ENTER, 3, 0, 0, 1, ENTER).
2) Check if the Machine Type is set for E7x-03.
3) As long as the Machine Type is correct, the console should
automatically be set for EP91 and the platform should automatically
be set for EP304.
4) Input the serial number for the console first.
5) The serial number configuration is as follows, then press OK:
- V:YY:MM;nnnnn
- V is the version. This will be a letter between B-Z (if the
console is version A, just leave this blank).
- Y is the year (e.g. 10, 11, 12).
- MM is the month (e.g. 08, 09, 10).
- nnnnn is the actual serial number.
Repeat this procedure to enter the platform serial number.
6) The example shows the console automatically set for EP91 a
version of C, a year of 2011, a month of 09 (September), and a
serial number of 00003.
The example shows the platform automatically set for EP304, a
version of A, a year of 2011, a month of 09 (September), and a
serial number of 00005.