Matrix COSEC Door V4 Скачать руководство пользователя страница 7

14

13

Figure 7

Ÿ

Match the mounting hooks  (A, B,

C, D, E) on the plate with the
respective mounting slots (1, 2, 3,
4, 5) at the back of the device.
Refer figure 8.

Ÿ

Tilt the device to allow mounting hook A 

into slot 1. Straighten the device and then 
slide it down on the plate. 

Ÿ

Use the M 3x6 screw provided to

you to secure the bottom mounting
slot on the plate. Match E to 5 as in
figure 8.

A

B

C

D

E

1

2

3

4

5

Figure 8

1

2

3

4

5

6

7

8

9

0

ESC

ENT

Apply Power to the COSEC Door Controller and wait for the reboot cycle to complete. At 
power on, all four LEDs will glow and will be turned off at the end of booting cycle.

LED Status Indicators

Powering On the Device

The COSEC DOOR can be connected to the network over Ethernet, Wi-Fi, and Mobile Broadband.

The COSEC DOOR is pre-configured with a default IP address and Subnet Mask.

 Default IP Address: 192.168.50.1
 Default Subnet Mask: 255.255.255.0

You need to change the IP Address to connect the Door to the network. You can do this in one of 
the following ways:

1. From the DOOR display
2. From the DOOR Webpage

Allowed

Denied

Alarm

Network

Ÿ

 The ‘Network’ LED will start blinking with regular cadence indicating the current

network connection status as shown in the table below.

Orange

Blinking

Ethernet connection on, but not 
connected to COSEC Server

Red

Blinking

No Ethernet connection

Network

Green

Blinking

Door is connected to the 
COSEC Server

Color

Cadence

Meaning

LED 

Содержание COSEC Door V4

Страница 1: ...n it for future reference The information in this guide may change from time to time However Matrix Comsec reserves the right to make changes in product design and specifications without prior notice...

Страница 2: ...on Keys COSEC DOOR Front View Card Personality Module must be ordered seperately Card Personality Module CPM CPM Slot COSEC DOOR Rear View 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 1 2 1 2 3 4 5 6...

Страница 3: ...ettings of the Door Controller Preparing for Installation Step 1 Unpacking the DOOR Unpack COSEC DOOR and check your package contents Select a Location It must be a flat surface such as a wall close t...

Страница 4: ...rew holes along the markings you traced on the wall Cut out the rectangular hole on the wall Insert the screw grips into the holes you drilled Fix the Mounting Plate on the installation surface with t...

Страница 5: ...r supply cable 2 pin connector with a DC jack on one end into the power terminal PWR In C6 Care must be taken to maintain the correct polarity Connect the power adapter to the DC jack Plug the adaptor...

Страница 6: ...xiliaryinputport AUX C4 AuxiliaryOutput The Auxiliary output por t can be used for activating alarm devices like hooter energizesomedevices controlannunciation devices If you are connecting an alarm d...

Страница 7: ...d off at the end of booting cycle LED Status Indicators Powering On the Device TheCOSECDOORcanbeconnectedtothenetworkoverEthernet Wi Fi andMobileBroadband TheCOSECDOORispre configuredwithadefaultIPadd...

Страница 8: ...gh Ethernet cables Figure 9 Connecting as a Direct Door 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 0 ESC ESC ENT ENT 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 0 ESC ESC ENT ENT Connecting as a Panel Door To us...

Страница 9: ...Weight FOTW FOPW Built in PoE Built in Wi Fi Built in Bluetooth No No Yes IEEE 802 11 b g n Yes IEEE 802 11 b g n No No Yes IEEE 802 11 b g n No Yes Yes No No Yes RS 232 and Wiegand No No Internal 12...

Страница 10: ...20 19 www matrixaccesscontrol com Head Office 394 GIDC Makarpura Vadodara 390010 India Ph 91 1800 258 7747 Email Support MatrixComSec com MATRIX COMSEC V 1 July 19...

Отзывы: